41
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
Settings in table below are made with requirement for chimney draft of 10-12 Pa
Parameter
Display
PLB 15
PLB 25
PLB 40
Sevice code
******12
******12
******12
Cleaning Setup
Fan
700sec
700sec
700sec
Cleaner
20sec
20sec
20sec
Use Cleaner
On Start
On Stop
Clean Soot
60sec
60sec
60sec
Clean Ashes
300 sec
300 sec
300 sec
0300 cycles
0200 cycles
0100 cycles
Quiet Mode
22:00/06:00
22:00/06:00
22:00/06:00
Ignition First Feed
Feed
25sec
25sec
40sec
Cycle Setup
Heater
3min
3min
3min
Fan B/E
2min/20/40
2min/20/40
2min/20/50
Cycle Setup
Feed
4 sec
5 sec
6 sec
Pause
30 sec
30 sec
30 sec
Cycle
15
15
15
Max/Min Power
dT
5
o
C
5
o
C
5
o
C
Max Power Setup
Feed
3 sec
5 sec
8,3 sec
Cycle
20
20
20
Fan B/E
18/35
25/35
20/60
Min Power Setup
Feed
35%
35%
35%
Fan B/E
4/20
8/35
10/30
Auto Cleaning Setup
v 8:00
□ 00:00
v 14:00
□ 00:00
v 22:00
□ 00:00
Pellet Lvl Sensor
NO NC
Addons Activation
CH Pump
DHW Pump
Thermostat
CH Mode
Thermostat
Buffer
Room Thermostat
NO
NC
Burn On / Burn Out Setup
dT
05
o
05
o
05
o
Burn On
>95
o
/25min
>95
o
/25min
>95
o
/25min
Burn Out
85
o
<
85
o
<
85
o
<
Burner Feeder
Duty
300%
300%
300%
Set Temperature
80
80
80