7.5. Pellet burner connection to the fuel
hopper and pellet auger
Take the feeder chute flexible hose (from
the auger set). Using a bracket, clamp
one end of the hose onto the motor-end
outlet of the pellet auger.
- Remember – pellet auger must be
installed at 45° angle to the ground
horizontal surface.
- Fill the hopper with fuel (see table 2 for
parameters of the fuel types used)
- Plug the power cord of the pellet auger
into the indicated Schuko-type burner
socket on the left side of the burner
housing.
Diagram 10. Mounting the pellet burner Pell
to WBS Active boiler
1.
WBS Active boiler;
2.
Pellet burner Pell;
3.
Auger flexible pipe;
4.
Auger;
5.
Fuel hopper.
7.6. Connecting the pellet burner to the
mains power supply
Such connection must be
performed by a technician /
service shop authorized for such
operations.
Caution! ELECTRIC SHOCK
HAZARD!
-
Before opening the unit: switch
off the voltage and secure the
unit against accidental restart.
-
Observe installation instructions.
It is mandatory to assure a
backup power generator of
corresponding rated power! (see
13.2)
Improper cable connections may
damage the regulator!
The device may be damaged if
struck by a lightning. Make sure
it is unplugged during the storms.
It is imperative that the
installation of the sensor to
control the temperature in the
boiler. View a scheme 5 point 6.
ATTENTION! STB - thermostat
(located on the front panel of the
boiler) to be bound to the burner
according to wiring diagram 12.
The boiler must be connected to a
220V/50Hz mains using power plug (3
meters long, bound to the burner).
Create tight connection with the electrical
mains which complies with the local
regulations.