38
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
13.2. Technical parameters of WBS Active - Pell
WBS - A 20
- Pell 25
WBS - A 25
- Pell 25
Nominal heat output kW
17
22
Minimum
÷
maximum heat output
kW
5÷20
6÷25
Mass flow of exhaust gases,
min.÷ max. heat ouput kg/s
0,004÷0,012 0,005÷0,013
Dimensions of boiler WBS
burner Pell
Height H mm
1235
1235
Width L mm
540
540
Depth D mm
1250
1315
Water mantle volume
l
60
75
Combustion chamber volume
l
58
62
Mantle resistance, Δt=20, K Pa/mbar
8/0,08
9/0,09
Required chimney draught Pa/mbar
10/0,10
10/0,10
Insulation
Boiler
Doors
high-efficiency thermal wool
high-efficiency thermal wool
Average
power
consumtion
Boler WBS Active
W
60
60
Burner Pell
Firing-Up mode
W
~ 400
~ 400
Operate mode
W
~ 60÷70
~ 60÷70
Self-cleaning mode
W
~ 1300
~ 1300
Electric power supply V/Hz
230/50
230/50
Recommended fuel Pellets, class ENplus-A1; ENplus-A2; EN-B
Operating temperature range
°C
65 - 80
65 - 80
Operating pressure bar
3
3
Weight: boiler, burner / fuel hopper
kg
264/71
309/71
Cold water inlet A, mm
R1¼''/232
R1¼''/232
Hot water outlet B, mm R1¼''/1265
R1¼''/1265
Safety line sleeve (sensor or safety valve sleeve) К, mm
G½''/1075
G½''/1075
Safety heat evacuator inlet / outlet Е, mm
R½''/1072
R½''/1072
Flue
F ø
mm
150
945
150
945
J, mm
270
270
Flue chimney opening O, mm
150/70
150/70
Drain
Y, mm
G½''/232
G½''/232
Ash-and-soot tray
X
P
P