T-Modell - 04/05 - Ausgabe 08/04 - 201804286 - BUE-0006-04EN
187
14
Fault Search
14.5.2
Alde Heater/Boiler
14.5.3
Refrigerator
Fault
Cause
Remedy
Red indicator lamp "Fault" is lit
Air in the gas pipe system
Switch off and on again. After
two futile ignition attempts,
wait for 10 minutes before try-
ing again
Lack of gas
Open regulator tap and gas
isolator tap
Connect a full gas bottle
Defect of a safety element
Contact customer service
Red indicator lamp is not lit
Fuse is defective
Replace fuse on the trans-
former/rectifier
Fault
Cause
Remedy
Refrigerator does not switch
on when operating in 230 V
mode
No 230 V power supply
Connect 230 V power supply
230 V automatic circuit break-
er has triggered
Switch on 230 V automatic cir-
cuit breaker
230 V operating voltage too
low
Have an expert check the
230 V power supply system
Refrigerator does not switch
on when operating in 12 V
mode
Jumbo flat fuse (50 A) in the
starter battery is defective
Replace jumbo flat fuse (50 A)
in the starter battery
Flat fuse (20 A) in the starter
battery is defective
Replace flat fuse (20 A) in the
starter battery
Disconnector relay in the
transformer/rectifier is defec-
tive
Contact customer service
12 V operating voltage too low
Have an expert check the
12 V power supply system
Refrigerator does not cut in
when operating in gas mode
The "GAS" operating indica-
tor (Fig. 125,2) flashes yellow
(RM 7361 and RM 7401)
Lack of gas
Open regulator tap and gas
isolator tap
Connect a full gas bottle
Air in the gas pipe
Repeat ignition 3 or 4 times
In case of AES:
Indicator lamps "230 V",
"12 V" or "AUTO" (Fig. 126,4)
are not lit green
Refrigerator is turned off
Switch on the refrigerator with
energy selector switch
(Fig. 126,3)
No electrical operating voltage
Connect 230 V power supply
Let the vehicle engine run
Switch on or replace the fuse
Contact a specialist workshop
Summary of Contents for T-585
Page 2: ...Instruction Manual T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN ...
Page 10: ...1 10 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Introduction ...
Page 36: ...4 36 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN During the Journey ...
Page 74: ...6 74 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Living ...
Page 82: ...7 82 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Gas Fittings ...
Page 108: ...8 108 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Electrical Fittings ...
Page 134: ...9 134 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Appliances ...
Page 152: ...10 152 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Sanitary Fittings ...
Page 160: ...11 160 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Care ...
Page 172: ...12 172 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Maintenance ...
Page 192: ...14 192 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Fault Search ...
Page 214: ...16 214 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Technical Data ...
Page 226: ...17 226 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Helpful Notes ...