Insert the override key and turn it ant—clockwise, the door will open.
•
Once the safe is open you can change the batteries, programme a new finger etc.
•
To remove the override key turn it in an clockwise direction (The bolts will extend into the
locked position) then remove the key and replace the override keyhole cover.
•
N.B.
Keep the override key outside of the safe.
Low voltage warning:
•
The display will show “Low Voltage” when the batteries are running low as a reminder to
replace them.
Dual user setting:
•
As standard the lock is configured in single user mode. You can change this to a dual user
mode if you want to.
•
Enter the menu system as previously instructed
•
Scroll to ‘Settings’ and select this option by pressing the red code setting button.
•
Scroll to ‘Safety Mode’ and select this option by pressing the red code setting button.
•
Scroll to ‘Double Fingerprint’ and select this option by pressing the red code setting button.
•
Once you have selected the setting you want save this by pressing the “Return” button.
Opening in dual user mode:
•
Press the black button on the front of the keypad to reveal the fingerprint scanner and
buttons.
•
Present a valid fingerprint onto the scanner.
•
The screen will now read ‘Second fingerprint’
•
Present a second and different valid fingerprint onto the scanner.
•
The safe will open.
•
N.B. If there are more than two valid fingerprints registered in the safe any combination of
two fingerprints will open the safe.
•
N.B. If only one fingerprint is registered in the safe then it will continue to operate in single
user mode until such time as a second fingerprint is registered. When a second fingerprint is
registered the safe will automatically begin to operate in dual user mode/