background image

OPERATING 

INSTRUCTIONS

Enter default factory Manager-Code

1-2-3-4-5-6

Open the lock

For safety reasons, we have programmed the 

lock with its own unique reset code and 

provide a support service for the length of 

your warranty.

The unique reset code guarantee provides 

secure storage and support should you need 

to reset your lock in the future.

For further information regarding your lock or 

for support please contact us at

1)

1)

2)

1)

2)

1)

2)

3)

4)

5)

6)

1)

2)

1)

2)

1)

2)

1)

2)

3)

4)

1)

2)

3)

4)

Enter 0-0-0-0-0-0

Enter existing code, 1 beep

Enter new 6-digit code, 1 beep

Repetition of the new 6-digit code, 2 beeps

The Reset-Code cannot open the lock.

1 long beep means that the code is not   

allowed, or the identical code was not 

entered for repetition. Repeat steps 5 to 8.
For security reasons, we recommend 

changing the Manager-Code immediately

after the lock is put into operation.
The default Manager-Code 1-2-3-4-5-6 must   

be changed before other users

can be added.

Forgotten Code Guarantee

Change code

Open with Manager-Code/fingerprint

Press and hold "3", 2 beeps

All User-Codes have been deleted.

The Manager-Code/fingerprints do not change.

(deletes the User-Codes, all fingerprints and 

resets the Manager Code to the default factory 

setting)
Refer to section B.

Contact our office for support.

1) Open with Manager or user code/fingerprint

2) Press and hold "4", 1 beep

Delete all users

Reset lock

Switch off beeper

Open with Manager or user code/fingerprint

Press and hold "4", 2 beeps

Security level 1 = Code 

only 

(default factory setting)

Security level 2 = Fingerprint 

and

 code

Open with Manager or user code and fingerprint

Press and hold "5", 1 beep, followed by 1 beeps

Open with Manager or user code

Press and hold "5", 1 beep, followed by 2 beeps.

Change to security level 2 

(fingerprint 

and

 code)

Change to security level 1 (code only)

enquiries@burtonsafes.co.uk.

Switch on beeper

Security levels

C

A

B

G

H

I

J

K

Entering four (4) consecutive invalid codes 

will result in a penalty period of 5 minutes)

The unit beeps at 5-second intervals to indicate 

that it is in penalty time.

While the system is in penalty time, the buttons 

do not respond.

The penalty time is only interrupted by removing 

the battery, not shortened, or deleted. After 

reinserting the battery, the penalty time will 

continue until the 5 minutes have elapsed.

End of locking/penalty time - 1 long and 2 short 

beeps

Two (2) consecutive incorrect entries result in a 

further penalty period of 5 minutes.

A correct code entry interrupts the penalty 

sequence. Entering four (4) consecutive invalid 

codes will result in a penalty period of 5 

minutes.

Penalty time after four invalid code entries 

L

D

E

Open with Manager-Code/fingerprint

Press and hold "+", 1 beep

Place a fingerprint 4 times onto the fingerprint 

reader, remove your finger after

each single (1) beep

After reading your finger 4 times you will

hear 2 beeps to confirm the addition of the 

fingerprint

The Manager-Code can add up to 5

fingerprints

Open with Manager-Code/fingerprint

Press and hold "1", 1 beep

Enter new 6-digit code, 1 beep

Repetition of the new 6-digit code, 2 beeps

Adding the manager’s 

fingerprints

Add User-Code (up to two 

User-Codes can be added)

Change Battery

There is a pull-out compartment for a 9V 

battery on the bottom of the input unit.

To replace the battery, pull out the battery 

compartment first.

Open the battery compartment latch.

See Fig. 1.

See Fig. 2.

See Fig. 3.

See Fig. 4.

Pull out the battery compartment.

Remove the battery and replace it

with a new one.

Make sure that you place the new battery in 

correctly. The positive (+) and the negative (-) 

contact must be in the correct position.

Reinsert the battery compartment into the 

input unit and slide it up until the cover

rests against the input unit. Press the 

battery compartment latch until it is firmly 

and securely in place.

Low Voltage 

Indicator

After opening, the input unit may indicate 

that the battery voltage is too low by 

flashing and beeping several times.

The battery is very low, nearly empty and 

must be replaced with a new one 

immediately 

We recommend using Energizer™ or 

Duracell™ 9V ALKALINE batteries.

1

2

3

4

Fig. 1

Fig. 2

Fig. 3

Fig. 4

*

*

1)

2)

Opening with own User-Code/fingerprint

Press and hold "+", 1 beep

Add Fingerprints

F

3)

4)

Place a fingerprint 4 times onto the fingerprint

reader, remove your finger after

each single (1) beep

2 beeps confirm the addition of the fingerprint

Each User-Code can add up to 5 fingerprints.

*

**

*

*

**

***

1)

2)

3)

4)

Reviews: