background image

USER INSTRUCTIONS 

LOCKING: 

• Turn the bar handle counter clockwise until stop position is reached

CURRENT SUPPLY 

BATTERY CHANGE:

A series of beeps indicates that the battery is weak and must be replaced. Only use 9V ALKALINE - batteries! 

Burton Safes recommends .......... . 

., 

ALKALINE  BATTERY 

Press the catch on the top edge of the battery cover with a screwdriver and lever 

off 

the battery lid. Pull the battery 

out carefully until the battery clip is visible. Release the battery from the clip and replace. Re-engage the lid. Please 

ensure that the cable is not damaged. 

Burton Safes Limited  Brockholes Business Park, Rock Mill Road, Brockholes, Holmfirth HD9 7BN. t 01484 663 388  f 01484 666 338  enquiries@burtonsafes.co.uk  www.burtonsafes.co.uk 

EMERGENCY POWER SUPPLY: 

If the safe has run out battery please follow these instructions

:

H

old a 

9V

 

D

uracell battery to the front 

+

 

&

 -

connectors on the front of the safe as displayed

While keeping contact at all times with the 

battery press "On" and enter your current code 

then enter to access the safe

Once inside please follow the above instructions 

on how to change your battery 