Operating Instructions 

   

Busch Temperaturregler 

 

Offset function

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating Instructions | 1473-1-8396 

— 5 — 

   

Pos: 21 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Überschriften (--> Für all e D okumente <--)/1. Ebene/M  - O/Offset-Funkti onen @ 37\mod_1373544905078_15.docx @ 298599 @ 2 @ 1 

 

Offset function 

 

Pos: 22 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Bedi enung/T emperaturregler /Ei nstellungen Off-Set - 1099 @  37\mod_1373544852375_15.docx @ 298583 @  @ 1 

 

 

Fig. 2:  Offset function 

 
Reaching the selected room temperature strongly depends on the ambient conditions such as heating/cooling 
system capacity (5 K/h min.), room size, ambient temperature, insulation etc.  
 
That is why the values in the scale are merely guide values. To obtain a setting that is as accurate as possible, 
the adjusting knob (1) can be offset in 4 stages by a total of +/-6°C.  
 
To do so, pull off the control knob and cut off the position lug (2) on its underside using a suitable tool.  
 
Then shift the control knob by the desired correction temperature in relation to the vertical and put it back on. 
 
 

Pos: 23 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Überschriften (--> Für all e D okumente <--)/1. Ebene/S - T /Technische Daten @ 11\mod_1279185386320_15.docx @ 83019 @ 2 @  1 

 

Technical data 

 

Pos: 24 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Technische Daten/T emperaturr egler/T echnische Daten  1099  @  37\mod_1373544943578_15.docx @ 298615 @   @ 1 

 

 

General 

Nominal voltage 

230 V ~ ±10%, 50 / 60 Hz 

Switching capacity (inductive) heating 

10 (4) A, 230 V ~ 

Switching capacity (inductive) cooling 

5 (2) A, 230 V ~ 

  Connection 

1.5 mm² … 2.5 mm² 

Temperature adjustment range 

~ 5 to 30°C  (1 = 5°C | 2 = 10°C | 3 = 15°C | 4 = 20°C | 5 = 25°C | 6 = 30°C) 

Switching temperature difference * 

Approx. +/- 0.5 K 

Protection type 

IP 20, (EN 60529) 

Power loss (Relay off) 

0.5 W 

Switch contact (independent normally open 
contact) 

2  

Mode of operation (DIN EN 60730-1) 

1 B 

Degree of contamination (DIN EN 60730-1) 

Rated surge voltage (DIN EN 60730-1) 

4000 V 

 
*   Typical control operation can not always be attained for cooling areas close to the floor. When the device 

heats up due to high current loads, the set value should be checked especially in cooling operating mode and, 
if necessary, the set-point temperature should be raised. 

Pos: 25 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für  alle Dokumente <--)/++++++++++++ Seitenu+++++++++++ @ 9\mod_1268898668093_0.docx  @  52149 @   @ 1 

 

 

 

Summary of Contents for 1099 UHK

Page 1: ...ctions Busch Temperaturregler Pos 2 N eustruktur Online Dokumentation KN X Titelbl ätter Temper aturregler Titelbl att 1099 37 mod_1373543431500_15 docx 298504 1 Temperature controllers 1099 UHK 1099 UHKEA Ende der Liste für Textmar ke Cover ...

Page 2: ...chnis 19 mod_1320649044386_15 docx 109653 1 1 Safety 3 2 Intended use 3 3 Environment 3 4 Setup and function 4 4 1 Features of function and equipment 4 5 Operation 4 6 Offset function 5 7 Technical data 5 8 Installation and electrical connection 6 8 1 Requirements for the electrician 6 8 2 Mounting 6 8 3 Electrical connection 8 9 Commissioning 9 Ende der Liste für Textmar ke TOC ...

Page 3: ...ür all e D okumente 1 Ebene U Z U mwelt 18 mod_1302614158967_15 docx 103383 1 1 3 Environment Pos 11 Neustr uktur Online Dokumentati on KN X Sicherheitshinweise und Hinweise Für alle Dokumente Hinweise U mwelt Hi nweis U mwelt Hi nweis El ektr ogeräte 18 mod_1302763973434_15 docx 103500 1 Consider the protection of the environment Used electric and electronic devices must not be disposed of with d...

Page 4: ...d Funkti on Temperaturregler Funkti onen 1099 37 mod_1373543826093_15 docx 298519 1 1099 UHKEA 1099 UHK With manual switch for switchover between cooling OFF heating With external input for switchover between heating and cooling Pos 18 Neustr uktur Online Dokumentati on KN X Überschriften Für all e D okumente 1 Ebene A F Bedi enung 11 mod_1279185541649_15 docx 83043 1 1 5 Operation Pos 19 Neustr u...

Page 5: ...line Dokumentati on KN X Überschriften Für all e D okumente 1 Ebene S T Technische Daten 11 mod_1279185386320_15 docx 83019 2 1 7 Technical data Pos 24 Neustr uktur Online Dokumentati on KN X Technische Daten Temperaturr egler Technische Daten 1099 37 mod_1373544943578_15 docx 298615 1 General Nominal voltage 230 V 10 50 60 Hz Switching capacity inductive heating 10 4 A 230 V Switching capacity in...

Page 6: ...rect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect from power 2 Secure against being re connected 3 Ensure there is no voltage 4 Connect to earth and short circuit 5 Cover or barricade adjacent live parts Use suitable persona...

Page 7: ... Montage Temper aturregler M ontag e 1099 37 mod_1373545684031_15 docx 298631 1 Note Use only in dry rooms Fig 3 Installation No Function A Height 150 cm minimum distance 30 cm B Avoid mounting on thermal bridges C Avoid draught and direct sunlight D Avoid the heat radiation of external devices Fig 4 Position for putting on the adjustment wheel Fig 5 Putting on the adjustment wheel To put on the a...

Page 8: ...UHK Fig 6 Connection to a 2 pipe system 1099 UHKEA 1099 UHK Fig 7 Connection to a 4 pipe system Terminal designation Assignment Input 1099 UHK for switchover to cooling mode Output for controlling the heating load Output for controlling the cooling load Note At high humidity tendency toward thunder storms during cooling mode attention should be paid to dew formation on the cooled surface Cooling s...

Page 9: ...KN X Inbetriebnahme Temperaturregler Inbetriebnahme 1099 37 mod_1373547005250_15 docx 298663 1 Note When the temperature controller is used for the first time it has to be taken into account that the switching point precision is not reached until about 1 2 hours of operation after installation It is recommended to set a temperature that is higher heating operation or lower cooling operation than a...

Page 10: ...tice We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The d...

Reviews: