KNX control elements and application parameters
Control element "Audio control"
Product manual 2CKA001473B5342
│
195
Value for decrease
:
Options:
0
1
The parameter is used to send the command for "Decrease volume" with "0" or "1".
– 1 x 4 bit
: Commands of a volume button are sent with 4 bit. No additional parameters
available.
-
1-byte value [0 - 255]
: The value of a volume button is sent as 1-byte value without a
sign. The following supplementary parameters are available:
Change of volume [%]
:
Options:
Setting option from 1 - 50
The parameter is used to specify in which step widths the volume is raised or lowered.
Telegram is repeated every [sec.]
:
Options:
Setting option from 0.25 - 1.25 seconds
The parameter is used to specify the space of time between two telegrams.
10.14.4 Use of ON/OFF button
Options:
Deactivated
Activated
–
Deactivated
: No ON/OFF button is enabled. No additional parameters available.
–
Activated
: The ON/OFF button is enabled. The following supplementary parameter is
available:
Object type ON/OFF button
:
Options:
1 bit
1-byte value [0 - 255]
The parameter is used to specify the size of the communication object for sending
telegrams.
– 1
bit
: Commands of an ON/OFF button are sent with 1 bit (0 or 1). The following
supplementary parameters are available:
Value for ON
:
Options:
0
1
The parameter is used to send the command for "ON" with "0" or "1".
Value for OFF
:
Options:
0
1
The parameter is used to send the command for "OFF" with "0" or "1".
-
1-byte value [0 - 255]
: The value of an ON/OFF button is sent as 1-byte value without a
sign. The following supplementary parameters are available: