5-4 ASSE MBLY INSTRUCTIONS FOR INDE PE NDE NT H Y DRAULIC SYSTE M
WHEN THIS SYSTEM
IS
USED, THE OPEN CENTER PLUG
ON
THE CONTROL VALVE MUST BE USED.
Tractor P.T.O. Shaft
540
RPM Only
Pump Must Be
Chained "Up-Close"
To Tractor.
When unit is equipped with PTO pump and reservoir, and
operates in a fluctuating manner, check first the clamps
holding the large hose to the pump and tank, and oil level in
the tank. This is the most common cause of air in the lines.
17
90° Male
Eihr)ws
I
IH'
-
1-l
1 1
I
16"- 12" "0" Ring Boss Inlet
Return Flow
To Filter
Pressure
Hose To Valve
Return "Suction"/
Line Hose
1"
(25mm)
Inside Diameter
Route These Hoses Via
A Protected Area That Will Not Require
Removal Of Fittings When Loader Is
Removed From Tractor. DO NOT
ALLOW HOSES TO BECOME
PINCHED OR KINKED.