When using the DC output, turn Smart Throttle to the OFF position.
The DC current will be below 5A if turning on the Smart Throttle
without AC current output.
•
When charging batteries, person must be present to monitor the
voltage. Stop charging when the voltage of the batteries is above 16V.
Or it may cause battery explosion, resulting in serious injury or death.
•
To prevent the possibility of creating a spark near the battery, connect
charging cable first to the generator, then to the battery. Disconnect
cable first at the battery.
•
Before connecting charging cables to a battery that is installed in a
vehicle, disconnect the vehicles grounded battery cable. Reconnect
the vehicle’s grounded battery cable after the charging cables are
removed. This procedure will prevent the possibility of short circuit and
sparks if you make accidental contact between a battery terminal and
the vehicle’s frame or body.
•
Do not attempt to start an automobile engine while the generator still
connected to the battery. The generator may be damaged.
•
·Connect the positive battery terminal to the positive charging cord. Do
not reverse the polarity of the charging cables, or serious damage to
the generator and/or the battery may occur.
• The battery may give off explosive gases; keep spark, flames and
cigarettes away. Provide adequate ventilation when charging.
•
The battery contains sulphuric acid (electrolyte). Contact with skin or
eyes may cause severe burns. Wear protective clothing and a face
shield.
• If electrolyte gets on your skin, flush with water.
• If electrolyte gets in your eyes, flush with water for at least 15 minutes
Summary of Contents for G3000X
Page 35: ...Deficient AC output ...
Page 37: ...Wiring Diagram ...
Page 38: ...Exploded Parts View ...
Page 39: ......
Page 40: ......