7
Installation
Customer Helpline 0345 257 7271
•
•
.
If the kitchen furniture are higher than the
cooktop, it must be at least 10cm away from
the cooker's side.
It is advised that there is a 2cm blank space
around the product for air circulation
The minimum heights from the pan support and
wall cupboards to cooker hoods with fan over the
product, are shown in figure 5. Thus, the cooker
hood must be at minimum 65cm height from the
pan support. If there is no cooker hood, this height
must not be less than 70cm.
Assembly of gas supply and leakage check
The connection of the appliance should be
performed in accordance with local and
international standards and regulations applicable.
First check what type of gas is installed on the
cooker. This information is given by a sticker on
the back of the cooker. You can find the
information related to appropriate gas types and
appropriate gas injectors on technical data table.
Check that the feeding gas pressure is compliant
with values on the technical data table, to be able
to get the most efficiency and to ensure the least
consumption. If the pressure of used gas is
different than these values stated or not stable in
your area, it may be required to assemble an
available pressure regulator on the gas inlet. It is
certainly required to contact to the authorized
service to make these adjusments.
The points that must be checked during flexible hose
assembly
If the gas connection is made by a flexible hose
that is fixed on the gas inlet of appliance, it must
be fixed by a pipe collar as well. Connect your
appliance with a short and durable hose that is as
close as possible to the gas source. The hose's
permitted maximum lenght is 1.5m. The hose that
brings gas to the appliance must be changed once
a year for your safety.
The hose must be kept clear from areas that may
0
heat up to temperatures in excess of 90 C. The
hose must not be ruptured, bent or folded. It must
be kept clear of sharp corners, moving things, and
should not be defective. Before assembly, it must
be checked whether there is any production
defect.
As gas is turned on, all connection parts and hose
must be checked with soapy water or leakage
Gas connection
fluids. No bubble should appear. If there are
bubbles, check the connection joint and redo the
test. Do not use naked flame to check gas
leakage. All metal components used during gas
connection must be clear of rust. Also check the
expiry dates of components to be used.
The points that must be checked during fixed gas
connection assembly
To assemble a fixed gas connection (gas connection
made by threads, e.g. a nut), there are different
methods used in different countries. The most
common parts are already supplied with your
appliance. Any other part can be supplied as spare
part.
During connections always keep the nut on the gas
manifold fixed, while rotating the counter-part. Use
spanners of appropriate size for safe connection. For
all surfaces between different components, always
use the seals provided in the gas conversion kit. The
seals used during connection should also be
approved to be used in gas connections. Do not use
plumbing seals for gas connections.
Remember that this appliance is ready to be
connected to gas supply in the country for which it
has been produced. The main country of destination
is marked on the rear cover of the appliance. If you
need to use it in another country, any of the
connections in the figure below can be required. In
such a case, contact local authorities to learn the
correct gas connection.
It is required to call the authorized service to be
able to make the gas connections appropriately
and in compliance with safety standards.
Surely do not use any match or
lighter for control of gas leakage
For some countries, the gas inlet type can be
different for NG/LPG gases. In such a case,
remove the current connection components and
nuts (if any) and connect the new gas supply
accordingly. In all conditions, all components used
in gas connections should be approved by local
and/or international authorities. In all gas
connections, refer to the “Assembly of gas supply
and leakage check” clause explained before.
ATTENTION!
.
Changing the gas inlet:
Adapter
Gas Pipe
Gas Pipe
Gas Pipe
Gas Pipe
Seal
Seal
Seal
Hose
Fitting
Gas Hose
with Collar
Mechanical
Gas Hose
Mechanical
Gas Hose
Mechanical
Gas Hose
Figure 6
!