8
RED LED ERROR LIGHT
A red LED error light is installed inside the main fridge light housing.
The number of flashes corresponds to the
following error type.
NO. OF
FLASHES
ERROR CODE
1
BATTERY PROTECTION CUT-OUT
The voltage is outside the cut-out setting.
2
TOO MANY START ATTTEMPTS (OR FAN OVER CURRENT)
This generally indicates the compressor has had too many start attempts due to battery
protection cut-out. It could also indicate fan overload of more than 0.5A but this is extremely
rare.
3
MOTOR START ERROR
The rotor is blocked or the differential pressure in the refrigeration system is too high (>5
bar)
4
MINIMUM MOTOR SPEED ERROR
Refrigeration system is overloaded, and motor cannot maintain minimum speed (1850 rpm)
5
THERMAL CUT-OUT
Refrigeration system overloaded or ambient temperature is too high.
6
THERMOSTAT FAILURE
The NTC thermistor has a short circuit or no connection
TECHNICAL SPECIFICATIONS
DC230-X
COMPRESSOR
Secop BD50
VOLTAGE
12 V / 24 V DC
MAX CURRENT
7.5 A / 3.75 A
POWER
80 W
REFRIGERANT
R134a (100g)
EXTERNAL
DIMENSIONS
(mm)
W 595
D 575
H 1460
NETT WEIGHT
51kg
For after sales service and enquiries, please contact:
BUSHMAN FRIDGES
3 Contour Close Research VIC 3095
(03) 9437 0737
info@bushman.com.au
Version 1.1 Jul 2022