background image

A 100% AUSTRALIAN OWNED FAMILY 

COMPANY SINCE 1982

WARRANTY   

 

 

DP Refrigeration trading as Bushman Portable Fridges ABN 89 152 366 478 (Bushman) warrants, to the original owner, that this product is free 
from defects in workmanship and material for a period of three years (5 years for the compressor only) from the purchase date. This warranty shall 
be limited to repairing or replacing, at Bushman’s option and without charge to the purchaser, defective components.  All warranty work shall be 
performed at a Bushman approved facility.  Shipping charges related to returning the product to the Bushman facility are not covered under this 
warranty.  However, this warranty covers shipping charges related to returning the repaired product to the customer. This warranty does not apply 
to damage or wear to the product caused by accident, abuse, misuse, neglect, unauthorized alteration or repair, or if the product was not operated 
in accordance with Bushman printed installation and operating instructions.  To obtain service under this warranty, the defective product must 
be returned to Bushman together with original purchase receipt. Any product repaired or replaced under this warranty will be warranted for the 
balance of the warranty period with respect to the original purchased product.

3 Contour Close, Research VIC 3095 Australia 

P

 +61 3 9437 0737

E

 aus@bushman.com.au 

www.bushman.com.au

MEASUREMENTS  

(3) CHECK ALL CONNECTIONS

Check all connections and solder points inside 

all sockets and plugs. Check your car 12 V socket 

connection by turning on the fridge and wiggling 
the connections to see if the power light flickers.

REPAIR CAR WIRING  

OR BATTERY

REPLACE  

CONTROL PANEL

(CONTACT  

HEAD OFFICE)

REPLACE LEAD OR 

REPAIR CONNECTION 

(1) USE A DIFFERENT POWER SUPPLY

Run the fridge using a 240V to 12V adaptor. If 

not available, use a different outlet with the car 

running, or in a different car.

(2) OVERRIDE THE CONTROL PANEL

Flick the override switch located on the back of the 

Bushman control panel, then turn on the fridge. 

This will bypass the control panel and run the 

compressor non stop. For normal operation the 

switch must be set to off.

FRIDGE RUNS

FRIDGE RUNS

 FAULTY CONNECTION

TROUBLESHOOTING FLOW CHART

We solve 9 out of 10 Bushman issues by using this flow chart:

DP Refrigeration  
Trading as Bushman Portable Fridges 

ABN 89 152 366 478 

THE 

ORIGINAL 

BUSHMAN 

FRIDGE 

FREEZER

12V / 24V / 240V : 35L – 52L

OWNERS MANUAL &  

OPERATING INSTRUCTIONS

MODEL: SC 35-52 

PLEASE READ CAREFULLY BEFORE  

USE AND INSTALLATION

A 100% AUSTRALIAN OWNED FAMILY 

COMPANY SINCE 1982

Reviews: