INSTALLATION INSTRUCTIONS
It is advisable to clean the inside of the absorption refrigerator with lukewarm water using a mild detergent,
and then to dry it thoroughly prior to use.
LEVELLING AND VENTILATION
The refrigeration system of the cabinet is designed to operate with the cabinet located on a flat surface. Avoid
tilting the cabinet side.
If the cabinet must be tilted on an angle for handling or moving purposes, allow it to sit in an upright position
20 to 30 minutes prior to plugging it in and starting the cooling of the storage compartment.
For electrical models - Grounding plug and socket should be provided in accordance with local regulations.
The cable-size should meet the refrigerator’s requirements. The unit must be connected to proper electrical
network, which is shown on the nameplate, through an omnipoplar circuit-breaker. To assure the proper
function of the refrigerator.
Please observe the following recommendations.
To ensure correct circulation, the unit should be kept 2.5 cm away from the rear wall and possible side walls.
The clearance above the refrigerator should be at least 100 mm.
Locate the unit away from direct sunlight. This will enable you to obtain the best performance and save
energy.
Further the room should have a window (which can be opened) or a door to the outside.
It is important that the refrigerator is not subject to radiation of heat from a stove etc.
For best performance also at high ambient temperatures there must be a free air circulation over the cooling
unit at the rear of the refrigerator.
The refrigerator is designed for a free-standing installation.
Ventilation must be in accordance with AS
/NZS
5601 -
Gas Installations.
In general, the appliance should
have adequate ventilation for complete combustion of gas, proper flueing and to maintain temperature of
immediate surroundings within safe limits.
At about 2
.
5cm
From the side
Wall
Wall
Rear
From
above
2
.
5cm
2
.
5cm
2
.
5cm