Operation
Now that the Gas Hot Water Shower has been prepared for our intended use, we
can set it up for operation.
1.
Find a suitable sturdy, non-combustible vertical surface to hang the unit. The unit
should be at least 300mm clear from the sides, 1000mm from above and 1400mm
from below, of all combustible surfaces, fabrics, flammable materials & people.
Hang the appliance on a suitable vertical surface by the top hanger attached to
the back cover of the heater.
The appliance is ready to be connected to both the gas and the water source.
2.
Connect the Gas Hose to the
LCC27 LPG cylinder. Hand-tighten the
connection in a clockwise direction.
Open gas tap on cylinder one full turn
anti-clockwise and then check the
connections for leaks with soapy water.
DO NOT use a flame.
If a leak is
detected, turn the cylinder valve off
(close), check seals and retighten all
connections and retest.
3. IMPORTANT
4.
Once you determine that there are
no leaks present with the gas valve
open, turn the cylinder valve to the off
(close) position.
Notice: Position the gas cylinder away and to the side of the appliance; never
place the gas cylinder directly beside or above the appliance.