Note 2 (Water Temperatures):
For higher temperatures, increase the HEAT
SETTING control and decrease the WATER FLOW control. Switch the TEMPERATURE
CONTROL from MIN to MAX will increase the temperature further.
A temperature in excess of 50°C will activate the Over Temperature Safety Sensor
and will shut down the burners. To relight the burner you will need to either:-
- Turn the switch off on the unit and allow cool water to flow through the unit until it
drops the internal temperature low enough to reignite the burner.
- Turn the water flow and gas off, allow unit to cool for 30min then reignite.
IMPORTANT – Water remaining in the heat exchanger while the flow is stopped
may become very hot. It will require water to flow through the unit for a short time
to clear the hot water. The user must check the temperature output to ensure it is
suitable and not too hot before showering.
Note 2:
When using the 12V Pump provided with the water regulator knob set
to “low”, a small amount of pulsing may be experienced at the shower rose.
This is normal.
Note 3:
After use, turn the gas cylinder valve off, wait for the flame to go out,
then turn the appliance control valve off.
WARNING
| Gas Hot Water Shower
Page 16
Summary of Contents for CSG010
Page 1: ...CSG010 ...