8.0 MACHINE ASSEMBLY
After having freed the various components from the
packing check that they are complete, and that there
are no anomalies, then comply with the following in-
structions for the assembly of the components making
use of the attached series of illustrations.
8.1
Anchoring system
The packed machine is fixed to the support pallet
through the holes prearranged on the frame. Such
holes can be used also to fix the machine to the ground,
through floor anchor small blocks (excluded from sup-
ply). Before carrying out the definitive fixing, check that
all the anchor points are laid down flat and correctly
in contact with the fixing surface itself. If not so, insert
shimming profiles between the machine and the fixing
lower surface, as indicated in
Fig.
5
.
Fig. 5
a
= 830 mm
b
= 590 mm
• Execute 4 holes with 10 mm diameter on the floor
by the holes on the bottom floor;
• insert the small blocks (excluded from supply) into
the holes;
• fix the machine to the ground with 4 M8x80 mm
screws (excluded from supply) (
Fig. 5 ref. 1
) (or
with 4 8x80 mm stud bolts (excluded from supply)).
Tighten the screws with an approximate tightening
torque of 70 Nm.
• Before fixing completely the machine to the ground,
flush its rear part rotating its feet (
Fig. 6 ref. 1
).
Fig. 6
CAPTURE 4 - CAPTURE 4 FI
7104-M007-4_B