INSTRUCTION, USE AND
MAINTENANCE MANUAL
GB
Page 13 of 67
3. Connect the mains pneumatic power supply by us-
ing the union placed on filter unit of the machine.
The pressurized pipe coming from the mains must
have a section of 10x19 (see
Fig. 9
).
Fig. 9
9.0 ELECTRICAL CONNECTIONS
EVEN THE TINIEST PROCEDURE
OF AN ELECTRICAL NATURE
MUST BE CARRIED OUT BY PRO-
FESSIONALLY QUALIFIED STAFF.
BEFORE CONNECTING THE MA-
CHINE MAKE SURE THAT:
• THE MAIN POWER RATING COR
-
RESPONDS TO THE MACHINE
RATING AS SHOWN ON THE
MACHINE PLATE;
• ALL MAIN POWER COMPO
-
NENTS ARE IN GOOD CONDI-
TION;
• THE ELECTRICAL SYSTEM
IS PROPERLY GROUNDED
(GROUND WIRE MUST BE THE
SAME CROSS-SECTION AREA
AS THE LARGEST POWER SUP-
PLY CABLES OR GREATER);
• MAKE SURE THAT THE ELEC
-
TRICAL SYSTEM FEATURES A
CUTOUT WITH DIFFERENTIAL
PROTECTION SET AT 30 mA.
The machine is supplied with
3
mt. of free cable. A plug
corresponding to the following requirements must be
connected to the cable:
• Conformity to Norm
IEC 309
• 230 Volt – 16A
• 2P + Ground
• IP 44
VERSION WITH
SINGLE-PHASE MOTOR
On delivery, the machine is pre-set to operate at a
single-phase voltage of 230V 50 Hz.
FIT A TYPE-APPROVED (AS RE-
PORTED BEFORE) PLUG TO THE
MACHINE CABLE (THE GROUND
WIRE IS YELLOW/GREEN AND
MUST NEVER BE CONNECTED TO
ONE OF THE TWO PHASE LEADS).
MAKE SURE THAT THE ELECTRI-
CAL SYSTEM IS COMPATIBLE
WITH THE RATED POWER AB-
SORPTION SPECIFIED IN THIS
MANUAL AND APT TO ENSURE
THAT VOLTAGE DROP UNDER
FULL LOAD WILL NOT EXCEED
4% OF RATED VOLTAGE (10%
UPON START-UP).
IN CASE OF A CHANCE SUPPLY
FAILURE, AND/OR BEFORE ANY
POWER SUPPLY CONNECTIONS,
MOVE THE PEDALS TO THE NEU-
TRAL POSITION.
CAPTURE 4 - CAPTURE 4 FI