INSTRUCTION, USE AND
MAINTENANCE MANUAL
Page 19 of 61
EN
THE PRESSURE RING (FIG. 17
REF. 1) MUST BE MOUNTED WITH
THE TEETH OR DISCHARGE SIDE
TOWARDS THE RING-NUT (FIG. 17
REF. 2).
12.0 CONTROL PANEL
The wheel balancers are equipped with a control panel
equipped with a keyboard to interact/operate the con-
trols presented in graphical form on the monitor.
On the monitor are displayed all the instructions for the
correct wheel balancing, for example indicating where
the operator shall fit adhesive or clip weights and the
balancing mode and/or option used, as well as correct
wheel rotation for inner/outer weights positioning.
Fig. 18
KEY
1 – Monitor
2 – Function push button (red)
3 – Function push button (yellow)
4 – Function push button (grey)
5 – Function push button (blue)
6 – Function push button (green)
7 – Previous page push button
8 – Next page/print push button
9 – Push button panel (keyboard with 7 keys)
LIBRAK350 - LIBRAK350PRO
1296-M024-01
13.0 WHEEL BALANCING
13.1 Switching the machine on and off
Press the "ON" switch (
Fig. 13 ref. 1
), located in the
rear part of the equipment.
Wait a few seconds up to the complete loading of the op-
erational program. The equipment is ready to operate
when the main screen "Home" appears on the monitor.
Fig. 19
1
2
3
4
A B C
KEY
A – Displaying operations/information area
B – Colours for identification of the buttons to be
used
C – Function icons
1 – Programs and measurements acquisition but-
tons
2 – Wheel spin push button
3 – Go to next page
4 – User management (if enabled) (user manage-
ment is not enabled on machine delivery)