INSTRUCTION, USE AND
MAINTENANCE MANUAL
Page 23 of 61
EN
Fig. 28
6
5
7
1
2
3
4
KEY
1 – Fundamental sine wave(fuchsia-coloured-
graph)
2 – Graph of detected eccentricity (blue)
3 – Slider that indicates the current position of the
rim ("12 o'clock") (red)
4 – Value in mm of the highest peak of imperfection
detected on the rim
5 – Value in mm of imperfection of the rim at the
current position
6 – Value in mm of the lowest peak of imperfection
detected on the rim
7 – Graph deleting button
The blue graph (
Fig. 28 ref. 2
) represents exactly
the geometric shape of the rim. The more the circle is
round and linear, the more the graph is flat, unlike the
more the circle has deficiencies, the more the graph
is large.
You can follow the eccentricity in the graph by manu-
ally turning the rim, the red-coloured-slider (
Fig. 28
ref. 3
), indicates the position of the rim in "12 o'clock"
position.
13.2.2 Programs setting through “Measure-
ments acquisition” screen page
From the “Home” page, press the
(
Fig. 19
ref. 1
) button to display "Measurements acquisition"
screen page below:
PRESS THE BUTTON
(
Fig. 19
ref. 1
)
TO DISABLE THE AUTO-
MATIC FUNCTIONS FOR THE
SELECTION OF THE BALANC-
ING PROGRAM OF DISTANCE-
D I A M E T E R C A L I P E R A R M ,
DESCRIBED IN PAR. 13.2.1.
TO BE ABLE TO REUSE THE
AUTOMATIC FUNCTION TO SE-
LECT THE WHEEL BALANCING
PROGRAM WITH GAUGE ARM, IT
IS NECESSARY TO RETURN TO
"HOME" PAGE, BY PRESSING THE
BUTTON
.
The selection of the wheel balancing program is pos-
sible in 2 ways:
- with highlighted program (yellow) by pressing the
or
until you see the desired program.
With this mode only the 11 standard programs can
be selected (DYN, ALU-S, ALU-S1, ALU-S2, STAT,
STAT-1, STAT-2, ALU-1, ALU-2, ALU-3, ALU-4).
IF THE PROGRAM NAME IS NOT
HIGHLIGHTED (YELLOW), PRESS
THE BUTTON
REPEATEDLY
UNTIL THE ABOVE CONDITION IS
REACHED.
LIBRAK350 - LIBRAK350PRO