INSTRUCTION, USE AND
MAINTENANCE MANUAL
GB
Page 12 of 68
8.0 MACHINE ASSEMBLY
8.1
Anchoring system
The packed machine is fixed to the support pallet
through the holes prearranged on the frame. Such
holes can be used also to fix the machine to the ground,
through floor anchor small blocks (excluded from sup-
ply). Before carrying out the definitive fixing, check that
all the anchor points are laid down flat and correctly
in contact with the fixing surface itself. If not so, insert
shimming profiles between the machine and the fixing
lower surface, as indicated in
Fig. 8
.
Fig. 8
a
= 1255 mm
b
= 600 mm
• Execute 4 holes with 12 mm diameter on the floor
by the holes on the bottom floor;
• insert the small blocks (excluded from supply) into
the holes;
• fix the machine to the ground with 4 M12x120 mm
screws (excluded from supply) (
Fig.
8 ref. 1
) (or
with 4 12x80 mm stud bolts (excluded from supply)).
Tighten the screws with an approximate tightening
torque of 70 Nm.
8.2
Fixtures contained in the packing
The packing case contains also the fixtures box.
Check that all the parts listed are there.
Code
Description
N.
G108A3
Head with lever
1
G108A41
Unit roll with bead wire
1
7503-M002-6_B
NAV26HW - NAV26HW.S - NAV26HW.ST
9.0 ELECTRICAL CONNECTIONS
EVEN THE TINIEST PROCEDURE
OF AN ELECTRICAL NATURE
MUST BE CARRIED OUT BY PRO-
FESSIONALLY QUALIFIED STAFF.
BEFORE CONNECTING THE MA-
CHINE MAKE SURE THAT:
• THE MAIN POWER RATING COR
-
RESPONDS TO THE MACHINE
RATING AS SHOWN ON THE
MACHINE PLATE;
• ALL MAIN POWER COMPO
-
NENTS ARE IN GOOD CONDI-
TION;
• THE ELECTRICAL SYSTEM
IS PROPERLY GROUNDED
(GROUND WIRE MUST BE THE
SAME CROSS-SECTION AREA
AS THE LARGEST POWER SUP-
PLY CABLES OR GREATER);
• MAKE SURE THAT THE ELEC
-
TRICAL SYSTEM FEATURES A
CUTOUT WITH DIFFERENTIAL
PROTECTION SET AT 30 mA.
The machines (NAV26HW and NAV26HW.ST) are
supplied with free cable of mt.
1,8
while the machine
(NAV26HW.S) is supplied with free cable of mt.
5,8
.
A plug corresponding to the following requirements
must be connected to the cable:
• Conformity to Norm
IEC 309
• 230 Volt – 16A
• 2P + Ground
• IP 44
Only for VARGNAV26HWD - version with inverter
• Conformity to Norm
IEC 309
•
185 Volt – 32A
•
3P + N + Ground
•
IP 44