INSTRUCTION, USE AND
MAINTENANCE MANUAL
A
B
The machine is supplied with
3
m of free cable. A plug
corresponding to the following requirements must be
connected to the cable:
• Conformity to Norm
IEC 309
• 230 Volt – 16A
• 2P + Ground
• IP 44
Fig. 12
10.3 Electrical connection
EVEN THE TINIEST PROCEDURE
OF AN ELECTRICAL NATURE MUST
BE CARRIED OUT BY PROFESSIO-
NALLY QUALIFIED STAFF.
BEFORE CONNECTING THE MA-
CHINE MAKE SURE THAT:
• THE MAIN POWER RATING COR
-
RESPONDS TO THE MACHINE
RATING AS SHOWN ON THE
MACHINE PLATE;
• ALL MAIN POWER COMPO
-
NENTS ARE IN GOOD CONDI-
TION;
• THE ELECTRICAL SYSTEM
IS PROPERLY GROUNDED
(GROUND WIRE MUST BE THE
SAME CROSS-SECTION AREA
AS THE LARGEST POWER SUP-
PLY CABLES OR GREATER);
• MAKE SURE THAT THE ELEC
-
TRICAL SYSTEM FEATURES A
CUTOUT WITH DIFFERENTIAL
PROTECTION SET AT 30 MA.
As envisaged by the regulations in force, the machine is
not equipped with a master circuit breaker, but simply
has a plug-socket connection to the electrical mains.
FIT A TYPE-APPROVED PLUG
TO THE MACHINE CABLE (THE
GROUND WIRE IS YELLOW/GRE-
EN AND MUST NEVER BE CON-
NECTED TO ONE OF THE PHASE
LEADS).
MAKE SURE THAT THE ELEC-
TRICAL SYSTEM IS COMPATIBLE
WITH THE RATED POWER AB-
SORPTION SPECIFIED IN THIS
MANUAL AND APT TO ENSURE
THAT VOLTAGE DROP UNDER
FULL LOAD WILL NOT EXCEED
4% OF RATED VOLTAGE (10%
UPON START-UP).
VERSION WITH
SINGLE-PHASE MOTOR
On delivery, the machine is pre-set to operate at a
single-phase voltage of 200 ÷ 265 V - 50/60 Hz.
FAILURE TO OBSERVE THE ABO-
VE INSTRUCTIONS WILL IMME-
DIATELY INVALIDATE THE WAR-
RANTY.
10.4 Working area modification
After the delivery, the machine is prearranged to op-
erate on wheel of 41” maximum diameter and a rim
diameter (10” - 26”). It’s also possible to move the tools
column to enlarge the working area from 43” (with rim
diameter of 12” - 28”) up to 45” (with rim diameter of
14” - 30”) (see
Figure 12
).
SEIDO.30 - SEIDO.30FI
7105-M005-10_B