Control and display elements
Butzbach GmbH Industrietore
Original operating manual sliding doors_V1
13/01/2021
24
Wiring diagram
symbol
Control cabinet design
Description
Use as an isolating device and EMERGENCY
SHUTOFF switch.
Key switch or dial with the functions 0 and 1
Indicator light that lights up in different colours
depending on the function (white, red, yellow)
Control elements
Description
Main switch
Use as an isolating device and EMERGENCY SHUTOFF switch.
Control voltage key
switch
Turn on (1) or turn off (0) the control voltage to the door system
Track heating dial*
Dial with the functions
manual, 0
and
automatic
Key switch for
bypassing wind sensor*
For bypassing the wind sensor in EMERGENCY situations
0
= no bypass;
1
= bypass of wind sensor
Attention!
Operation only by authorised maintenance personnel!
*optional
Display elements
Description
“Control voltage on
”
indicator light
White light that lights up if the control voltage is switched on.
“BMA activated”*
indicator light
Light that lights up if the fire alarm system is activated.
“Door system
authorised
”* indicator
light
Light that lights up if operation of the door system has been authorized.
“Collective error
message
”* indicator
light
Light that lights up if there is an error in the door system.
“Track heating on”*
indicator light
Light that lights up if the track heating is turned on.
“SKS activated”*
indicator light
Light that lights up if the safety edge control was activated.
“Door closed”* indicator
light
Light that lights up if the door is closed.
“Doors of door leaf X”*
indicator light
Light that lights up if the door in the respective door leaf is opened.
“Wind speed > 70
km/h
”* indicator light
Light that lights up if the wind speed exceeds 70 km/h.
*optional
Attention!
You can find the additional optional control and display elements for your individual control cabinet in the
wiring diagram!
Information for authorised electricians!
You can find additional information about operation of the door
system in the wiring plan.