BV-WF-01-LV VENTILADOR DE PARED 

Guía de Instalación

ADVERTENCIA

Porfavor, lea estas instrucciones detenidamente antes de instalar, operar o reparar el ventilador. Conserve esta guía para futura referencia. 

6

REPUESTOS Y MANTENIMIENTO

1

2

4

5

6

12

3

3

3

8

9

7

11

10

13

14

15

1. Grille

2. Sheet Metal Nut

3. Sheet Metal Screws 

4. Motor Mounting Bracket

5. Motor

6. Blade

7. Wiring Box Cover

8. Green Ground Screw

9. Wiring Box

10. Housing 

11. Receptacle 

12. Spring

13. Adjustable Duct

14. Wall Cap

15. Aluminum Ring

1.  Solo para ventilación general. No lo use para 

agotar materiales y vapores peligrosos o 

explosivos.

2.  Para evitar daños del motor y los impulsores 

ruidosos y/o desequilibrados, mantenga 

el rociador de paneles de yeso, polvo de 

construcción, etc. fuera de la unidad de 

potencia.

3. 

Lea  la  etiqueta  de  especificaciones  del 

producto para obtener más información y 

requisitos.

4.  No utilizar en el baño.

5.  Para reducir el riesgo de lesiones, instale el 

ventilador  al  menos  a  2,1  m  (7  pies)  sobre 

el piso.

PRECAUCIÓN

USO Y CUIDADO

DIAGRAMA DE CABLEADO

PARA REDUCIR EL RIESGO DE INCENDIO, 

DESCARGA ELÉCTRICA O LESIONES A LAS 

PERSONAS, OBSERVE LO SIGUIENTE:

1.  Utilice esta unidad solo de la manera 

prevista por el fabricante. Si tiene preguntas, 

comuníquese con el fabricante a la dirección 

o número de teléfono que aparece listado en 

la garantía.

2.  Antes de reparar o limpiar la unidad, apague 

el panel de servicio y bloquee los medios de 

desconexión del servicio para evitar que la 

fuente de poder se encienda accidentalmente. 

Cuando los medios de desconexión del 

servicio  no  puedan  bloquearse,  fije  de 

forma segura un dispositivo de advertencia 

prominente, como una etiqueta, al panel de 

servicio.

3.  El trabajo de instalación y el cableado 

eléctrico deben ser realizados por personas 

calificadas de acuerdo con todos los códigos y 

estándares aplicables, incluidos los códigos y 

estándares de construcción con clasificación 

de resistencia al fuego.

4. 

Se necesita suficiente aire para la combustión 

adecuada y el escape de gases a través de 

la chimenea del equipo de combustión para 

evitar la extracción de aire. Siga las pautas 

y las normas de seguridad del fabricante del 

equipo de calefacción, como las publicadas 

por la Asociación Nacional de Protección 

contra  Incendios  (NFPA)  y  la  Sociedad 

Americana de Ingenieros de Calefacción, 

Refrigeración y Aire Acondicionado 

(ASHRAE),  y  las  autoridades  de  código 

locales.

5.  Cuando corte o taladre en la pared o el 

techo, no dañe el cableado eléctrico y otras 

utilidades ocultas.

6.  Los 

ventiladores 

canalizados 

siempre     

deben ventilarse al aire libre.

7.  Esta unidad debe estar conectada a tierra.

8.  Para reducir el riesgo de incendio, use solo 

conductos metálicos.

9.  El  voltaje  de  suministro  del  servicio        

eléctrico debe ser de 120V 60HZ.

ADVERTENCIA

: Apague la energia en el panel 

de servicio y bloquee el panel de servicio antes 

de limpiar o reparar este ventilador.

PARA LIMPIAR EL CONJUNTO DEL 

VENTILADOR:

Desenchufe el motor del receptáculo. Retire 

el  conjunto  del  motor  aflojando  los  tornillos  de 

montaje y girando el conjunto del motor. 
Aspire suavemente el conjunto del motor y el 

interior de la carcasa.
LAS PIEZAS METÁLICAS Y ELÉCTRICAS 

NUNCA DEBEN SUMERGIRSE EN AGUA.
CHEQUEAR PERIODICAMENTE LA 

REJILLA EXTERIOR EN BUSCA DE POLVO 

ACUMULADO, PELUSA, ETC; QUE PUEDAN 

INTERFERIR CON EL CIERRE CORRECTO DE 

LA REJILLA.

ADVERTENCIA

: NO ROCÍE EL AGUA EN LA 

REJILLA. EL DAÑO AL VENTILADOR PUEDE 

OCURRIR Y EL AGUA PODRÍA ENTRAR A LA 

CASA.
No es necesario engrasar el motor de este 

ventilador.

Summary of Contents for BV-WF-01-LV

Page 1: ...blished by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 This unit must be grounded 8 To reduce risk of fire use only m...

Page 2: ...en wire to box using green ground screw NOTE Fan can be installed in outside walls up to 10 thick Walls less than 6 thick will not use the adjustable duct Choose a location with no obstructions Fan can be operated by a wall switch or speed control available separately WARNING When cutting or drilling into wall do not cut existing electrical wiring CAUTION Do not mount fan above cooking surface CAU...

Page 3: ...ly including inside and outside wall coverings Stretch the adjustable duct slide it over the housing and tape it in place non tapered end of flexible duct may need to be shortened to fit Position fan housing in wall Drill pilot holes through center of slots in mounting flange 4 6 5 TAPE HERE ...

Page 4: ... TAPE HERE 8 CAULK EDGES 9 Complete this step only if adjustable duct is used From outside slip adjustable duct into the aluminum ring attached to the wall cap and tape the joint Compress the excess duct back into the opening by positioning the wall cap against the outside wall Fasten wall cap to outside wall with screws and caulk around the edges ...

Page 5: ... quality product It was made with care and BV offers a limited one year warranty against any manufacturing defects as long as it has been used as directed BV will replace any product showing such manufacturing defects This warranty does not include labor costs for the installation or removal of the fan For warranty assistance call 866 721 3888 5 MOUNTING SCREW ...

Page 6: ...etiqueta al panel de servicio 3 El trabajo de instalación y el cableado eléctrico deben ser realizados por personas calificadas de acuerdo con todos los códigos y estándares aplicables incluidos los códigos y estándares de construcción con clasificación de resistencia al fuego 4 Se necesita suficiente aire para la combustión adecuada y el escape de gases a través de la chimenea del equipo de combu...

Page 7: ... tornillo de tierra verde NOTA El ventilador se puede instalar en paredes exteriores de hasta 10 de grosor Las paredes de menos de 6 de grosor no utilizarán el conducto ajustable Elija un lugar sin obstrucciones El ventilador puede ser operado por un interruptor de pared o control de velocidad disponible por separado ADVERTENCIA Al cortar o taladrar en la pared no corte el cableado eléctrico exist...

Page 8: ...es interiores y exteriores Estire el conducto ajustable deslícelo sobre el alojamiento y péguelo con cinta adhesiva en su lugar es posible que sea necesario acortar el extremo no cónico del conducto flexible Coloque el alojamiento del ventilador en la pared Taladre agujeros piloto a través del centro de las ranuras en la brida de montaje 4 6 5 CINTA ADHESIVA AQUÍ ...

Page 9: ...aso solo si se utiliza un conducto ajustable Desde el exterior deslice el conducto ajustable dentro del anillo de amluminio unido a la tapa de la pared y pegue con cinta adhesiva el conjunto Comprima el exceso del conducto de nuevo en la abertura colocando la tapa de la pared contra la pared exterior Sujete la tapa de la pared a la pared exterior con tornillos y calafatee alrededor de los bordes C...

Page 10: ...d Fue hecho con cuidado y BV ofrece una garantía limitada de un año contra cualquier defecto de fabricación siempre que se haya utilizado según las instrucciones BV reemplazará cualquier producto que muestre tales defectos de fabricación Esta garantía no incluye los costos de mano de obra para la instalación o extracción del ventilador Para asistencia con la garantía llame al 866 721 3888 10 10 TO...

Reviews: