GasAlertClip English Instruction Sheet
D2087/2 Page 1
Trimmed and folded dimensions: 4.125 (w) x 5.875 (H)
BW TECHNOLOGIES
GasAlertClip
2 Year Gas Detector
Instruction Sheet
Introduction
The GasAlertClip gas detector (“the detector”) warns of hazardous gas at
levels above (below for oxygen deficiency) a factory set alarm setpoint. The
detector is a personal safety device that stores and transmits gas alarm
event data. It is your responsibility to respond properly to the alarm.
Models with internal vibrator
alarm and event logging
Gas Monitored
GA24A-H-EL
hydrogen sulfide (H
2
S)
GA24A-M-EL
carbon monoxide (CO)
GA24A-S-EL
sulfur dioxide (SO
2
)
GA24A-X-EL
oxygen (O
2
)
GA-TC-1 Test Cap Accessory
The test cap accessory is designed to fit over the sensor when you test the
detector’s response to the target gas.
GPR-PRINTER Cordless Thermal Printer Accessory
The cordless printer accepts and prints stored gas alarm event data.
GA-TS02 Automatic Test Station Accessory
The test station is designed to automatically test response to gas.
D2087/2
BW1007-27-01-12.375X11.75-5187-2
© November 2002 BW Technologies. All rights reserved.
a
Safety Information - Read First
⇒
Warning: Substitution of components may impair intrinsic safety.
⇒
Do not activate the detector after the date on the package.
⇒
This product is a gas detector, not a measurement device.
⇒
Perform a self-test each day prior to use.
⇒
Make sure the sensor grill is free of dirt and debris.
⇒
Make sure the sensor grill is not covered.
⇒
Periodically test the sensor’s response to gas by exposing the
detector to a target gas concentration that exceeds the low alarm
setpoint. Manually verify that the audible and visual alarms are
activated.
⇒
Periodically calibrate the GasAlertClip O
2
.
c
Note:
This instrument contains a lithium battery. Do not mix with the solid
waste stream. Spent batteries should be disposed of by a qualified
recycler or hazardous materials handler.
International Symbols
Symbol
Meaning
h
Classified to both U.S. and Canadian Safety
standards by Underwriter’s Laboratories, Inc.
ATEX
Conforms to European Directive 94/9/EC – ATEX 95
g
European Explosion Protection
X
Conforms to European Union directives
Activating the Detector
Press
C
and hold for 5 seconds. The detector emits one beep, one flash
and one vibration*. Then the detector sets the life-remaining clock, performs
a self-test and displays the alarm setpoints. Once activated, the detector
cannot be turned off.
If the detector passes the self-test,
u
shows on the display and the unit is
ready for use. Instructions describing what to do in the event of a self-test
failure appear in the section “Self-Test Fail.”
*Vibrator models only.
A
Infrared download port*
B
Audible alarm
C
Visual alarm
D
LCD display
E
Clip
F
Test button
C
G
Sensor and sensor grill
*EL models only.