GasAlertMicroClip
Alarms
Stopping a Gas Alarm
The low and high alarms stop when the ambient gas level
returns to the acceptable range.
Note
If alarms are set to latch, press
C
to reset the
alarms.
The detector computes the TWA value based on OSHA
standards and the STEL value based on a user selectable
5 to 15 minute period (see
STEL Interval
).
To stop a TWA or STEL alarm, perform one of the following:
1. Deactivate
(see
Deactivating the Detector
) and
reactivate (see
Activating the Detector
) the
detector.
2.
Reset the TWA/STEL/MAX exposure readings
(see
Viewing Gas Exposures
).
Sensor Alarm
The detector tests for a missing or defective sensor on
activation and continuously thereafter. If a sensor fails the
self-test,
Err
appears above the gas bar of the failed sensor
(refer to the
Troubleshooting
section).
Low Battery Alarm
The detector tests the battery on activation and continuously
thereafter. Battery power is continually displayed during
normal operation. If the battery voltage is low, the detector
activates the low battery alarm.
The low battery alarm continues until you recharge the
battery. If the battery voltage drops too low, the detector
executes an automatic shutdown.
Note
If the confidence beep is on, the audible alarm
does not beep during a low battery alarm (see
Confidence Beep
). Typically, the low battery alarm
continues for 30 minutes before an automatic
shutdown.
Automatic Shutdown Alarm
If the battery voltage is in immediate danger of dropping
below the minimum operating voltage,
LOW BAT
and
L
display, the audible alarm beeps eight times, and the visual
alarm flashes eight times. The LCD then displays
OFF
before it deactivates and the detector stops normal
operation. Charge the battery. See the section,
Charging the
Detector
.
27