GasAlertMicroClip
Charging the Detector
•
Low Alarm Acknowledge
: When enabled, the
beeper can be disabled during low alarm if
C
is
pressed. The vibrator and alarm LEDs will function
normally (H
2
S, CO, and LEL sensors only);
The battery should be charged after each workday. To charge
the battery, deactivate the detector and insert the
GasAlertMicroClip charging adapter (as shown in the following
figure). Allow it to charge for 2-3 hours.
•
Force Calibration When Overdue:
Forces the
detector into mandatory calibration if a sensor is
overdue for calibration upon start-up;
The detector must be charged in a non-hazardous atmosphere
of 0°C-45°C (32°F-113°F).
To reach full battery capacity, allow the battery to fully charge
and fully discharge three times.
•
Cal Lock:
It allows the detector to auto zero, but span
needs to be conducted with an IR device;
•
Force Bump When Overdue:
Forces a bump check
if the sensor has exceeded its bump check interval;
•
Bump Due Lock:
Forces the detector to search for
an IR device to execute a bump check.
3.
Language
Enables the LCD’s language in English, French
(
Français
), German (
Deutsch
), Spanish (
Español
), or
Portuguese (
Português
).
Charging the Detector
a
Warning
The battery can only be replaced by the manufacturer.
Not complying with this might cause explosion danger.