PRODUCT INFORMATION
BULLETIN
105 Bonnie Drive
Butler, PA 16002
724-283-4681
724-283-5939 (fax)
www.bwieagle.com
AIR-EAGLE
®
XLT
900 MHz RF Receiver
MODEL 44P-8-ESTOP
DESCRIPTION
The A
IR
-E
AGLE
XLT
is an RF system designed for long range wireless
remote control of electrical apparatus in a variety of industrial applications.
This receiver has been specifically designed for E-Stop applications. It
links with an E-stop transmitter for failsafe operation. Dip switches allow
the user to select link-loss shutdown times, relay operation and whether
power must be recycled to reset the system. The relays are capable of
switching up to 5 amps @120VAC or 30VDC and can be directly
interfaced with the customer's equipment or P.L.C. Seven user selectable
frequencies allow multiple systems to be used in the same area. This
receiver is capable of receiving remote signals transmitted from up to
2500 feet away.
INSTALLATION
DISCONNECT AC Power from all equipment before installation.
1.
Mount the A
IR
-E
AGLE
XLT R
ECEIVER
in a convenient location.
2.
Select options & frequency (See OPTIONS & FREQUENCY SET-
UP)
3.
Install relay wiring to terminal strip.
4.
Install antenna onto connector located on the right side on the
enclosure.
5.
Connect AC power to the proper terminals in your control circuit.
TERMINAL STRIP WIRING
1
N/O Relay #1
7
N/O Relay #3
13 120 VAC - (Neutral)
2
C Relay #1
8
C Relay #3
14 120 VAC - (Hot)
3
N/C Relay #1
9
N/C Relay #3
4
N/O Relay #2
10 N/O Relay #4
5
C Relay #2
11 C Relay #4
6
N/C Relay #2
12 N/C Relay #4
GENERAL OPERATION
Prior to operation the user selects various options that control the link-loss
shutdown, relay activation and system reset. (See OPTIONS &
FREQUENCY SET-UP).
When power is applied to the receiver, all relays will be in their de-
energized state. When power is applied to the E-stop transmitter, it
immediately begins sending a beacon signal that causes the selected
relays in the receiver to energize, indicating the communications link.
Upon an E-stop command, the selected relays immediately de-energize.
Upon specified link-loss time, the selected relays de-energize. The system
will then need to be manually reset or will automatically come back online
as designated by the system operation option selected.
Dimensions (with mounting plate) 6.3” L x 4.8” W x 2.3” H
CONTROLS AND INDICATORS
.
LED1
Illuminated when power is applied to receiver
LED2
Illuminated when relay #1 is energized
LED3
Illuminated when relay #2 is energized
LED4
Illuminated when relay #3 is energized
LED5
Illuminated when relay #4 is energized
RF1
RF module that receives data from the remote
transmitter
REL1 thru REL4
Four SPDT output control relays