background image

OPERATIONS MANUAL

RESIDENTIAL FILTRATION SYSTEMS

WITH FLECK 2510 AIO CONTROL VALVE

PROFESSIONAL II SERIES

MODEL NO. ______________________

SERIAL NO. ______________________

The Blake Group

B W S

TM

Summary of Contents for PROFESSIONAL II Series

Page 1: ...OPERATIONS MANUAL RESIDENTIAL FILTRATION SYSTEMS WITH FLECK 2510 AIO CONTROL VALVE PROFESSIONAL II SERIES MODEL NO ______________________ SERIAL NO ______________________ The Blake Group B W S TM...

Page 2: ...STARTUP WATER TEST RESULTS IRON________________________PPM WATER TEST RESULTS MANGANESE_________________PPM WATER TEST RESULTS HYDROGEN SULFIDE___________PPM WATER TEST RESULTS FEEDWATER pH__________...

Page 3: ...design Do not use where water is microbiologically unsafe Installation Requirements WATER PRESSURE A minimum of 30 psi of water pressure 2 7bar is required for regeneration valve to operate effectivel...

Page 4: ...er tank from venting backwards up the feed water plumbing 5 If not factory installed assemble the deflector to the distributor tube Deflector Installation Put a thin layer of silicone lube around insi...

Page 5: ...A M every third day This ensures the right times for each step of the regeneration process Under normal circumstances these settings will not need to be altered and should not be changed The frequenc...

Page 6: ...e this occurs a regeneration cycle will be initiated at the Set Regeneration Time Water flow through the valve is indicated by the Flow Indicator that will flash in direct relationship to flow rate Ti...

Page 7: ...event of power failure the control shifts into a power saving mode The control stops monitoring water usage and the display and motor shut down but it continues to keep track of the time and day for a...

Page 8: ...le button again The service icon will stop flashing Regenerating Immediately Press and hold the Extra Cycle button for five seconds 1 The timer advances to Regeneration Cycle Step 1 backwash and begin...

Page 9: ...eration time may be changed to accommodate households with varying schedules however once set to meet water quality requirements the cycle duration times should not be changed 1 Backwash 14 minutes Du...

Page 10: ...gle Tank DO Day Override 3 Days between Regenerations RT Regeneration Time 12 00 AM Regeneration Time BW Backwash 14 Minutes for Backwash Cycle BD Air Draw 40 Minutes for Air Draw Cycle RR Rapid Rinse...

Page 11: ...iser tube to ensure that no filtration media or gravel falls down into the riser tube The riser tube should be firmly seated and centered in the tank and should be flush with the top of the tank openi...

Page 12: ...backwash The backwash cycle should continue unit the water runs clear The valve can ow be cycled to service and the bypass valve opened allowing treated water to enter the household piping Caution mos...

Page 13: ...the unit and contact technical support 2 Regen Failure The system has not re generated for more than 99 days or 7 days if the control type has been set to Day of Week Perform a Manual Regeneration to...

Page 14: ...2 8 216 259 2 324 432 Media Wgt cf Service Rate GPM perSq Ft Backwash Rate GPM per Sq Ft Bed Depth Inches Percent Bed Expansion 50lbs 5 12 to 18 24 to 36 20 to 40 35 to 40LBS 3 5 to 5 10 to 12 30 to 3...

Page 15: ...NOTES...

Page 16: ...DISTRIBUTED BY AIO MANUAL Rev APR 2018 Blake Water Solutions 4 New Park Road East Windsor CT 06088 Tel 860 243 1491 The Blake Group B W S TM P N XO2510AIO...