2021/02 - Indice de révision : E - Code : 37791
BIEN-ÊTRE
44/64
The trip values for protection against over currents are shown below.
Cross section of the copper power cable for a voltage drop less than 5.0%
Spa model
SP 2.18 and 3.17
SP 4.31
No blower
With blower
No blower
With blower
Current (A) absorbed
15 A
15 A
22 A
26 A
Max cable
length
5 m
2.5 mm²
2.5 mm²
2.5 mm²
2.5 mm²
10 m
2.5 mm²
2.5 mm²
2.5 mm²
4 mm²
15 m
2.5 mm²
2.5 mm²
4 mm²
4 mm²
20 m
4 mm²
4 mm²
4 mm²
6 mm²
Over
current
protection
trip value
Not
adjustable
19 A
16 A
25 A
32 A
Adjustable
Set the device to trip at the absorbed c 10 to 15 %
3.3.2 Preparation and connection of the remote installed spa pack (option)
A) Selecting the installation site and running the lines
The spa pack may be installed at a distance of up to 7.5 m from the spa.
The spa pack must not be installed at a height lower than 1.5 m below the water level. It must however be
installed at a height below the water line.
The installation site should be:
•
Well- ventilated,
•
Sheltered against the elements,
•
Protected against dust,
•
Not subject to streaming or the accumulation of rain water,
•
Allows the pipes and tubing between the spa pack and mounting plate to be run straight (no bends).
The pipes and tubing run between the spa pack and spa pack mounting plate should be protected against
trampling, impact, direct exposure to UV light and should not be in contact with sharp objects (sharp
stones, etc.).
They may be cut to length.
The path should be as direct as possible to facilitate the circulation of water between the spa pack and the
spa.
Summary of Contents for 31021000
Page 31: ...Notes 2021 02 Indice de r vision E Code 37791 BIEN TRE 31 64...
Page 32: ...Notes 2021 02 Indice de r vision E Code 37791 BIEN TRE 32 64...
Page 62: ...Notes 2021 02 Indice de r vision E Code 37791 BIEN TRE 62 64...
Page 63: ...Notes 2021 02 Indice de r vision E Code 37791 BIEN TRE 63 64...
Page 64: ...2021 02 Indice de r vision E Code 37791 BIEN TRE 64 64...