Resetting the display during operation:
If the time is to be adjusted during normal operation, press any key to illuminate the display, press the
[SET]
key once. The display will flash and indicate present time. Using the keys will alter the time - see
chapter 4.2 Operation (workflow).
Power loss:
The AMECS system will maintain the individual programming parameters of the water softener for a
few hours.
If the power cut lasts longer than a few hours, the control will flash “00:00“ when power is returned to
the control. The unit will continue to keep time from the moment power is restored. In this situation the
time of day will need to be reset.
Flow indicator:
During normal operation, a flow indicator will flash on the display at a rate of one litre per pulse when
water is passing through the softener.
Cleaning:
Your water softener may be cleaned using a damp cloth and a mild detergent. Do not use bleaches,
solvents or spirits as they may damage the surfaces.
Manual regeneration [RECHARGE] button:
Under normal operating conditions your water softener will regenerate automatically and you should
not normally have to regenerate the unit manually. If however a manual regeneration is required then
follow the procedure set out below.
1. Press any key to illuminate the display.
2. Momentarily pressing the button (symbol underneath the display and furthest to the right) will illu-
minate Recharge Tonight on the display and perform a regeneration at 2.00 a.m. regardless of the
remaining water softener capacity.
3. If the button is accidentally pressed a second time, this will clear the Recharge Tonight indicator
from the display and cancel the Recharge Tonight feature.
4. If the
[RECHARGE]
button is pressed down for six seconds, the controller will flash the Recharge
display and immediately commence the regeneration cycle which cannot be cancelled.
Adding regenerative salt:
Refill the salt no later than when
[SALt]
is indicated on the display or the current filling is 15 cm above
the base of the salt storage container.
Acknowledge - low SALt alarm:
NOTE!
f
This function is optional - not standard on all models.
Open the cover. Pour regenerative into the storage area.
Press
[SET]
and hold until the
[SALt]
display goes out. Refill the unit in such a way that no dirt can get
into the salt storage container (if necessary, clean the packages containing the salt before use).
Clean the salt storage area or brine cavity with clean water if it gets dirty.
Salt usage:
Your water softener is controlled by a microprocessor which constantly monitors water usage.
The system will build up a history of your water requirements and calculate the most economical
regeneration pattern. This will ensure a constant supply of softened water whilst maintaining high levels
of water and salt efficiency. As your water softener uses a proportional brining system, more frequent
regenerations do not necessarily mean high water / salt usage.
3