23
Manual
SOFTENER FER27-A6X
code P0011148 - Rev 1 - 15/03/2017
En
g
li
s
h
Put the softener (1) in place
Place the device in its defi nitive position (see
dimensions on the Scope of Delivery sheet)
The fl oor shall be clean and horizontal.
The controller unit
(2)
and the lid shall remain
accessible.
Set and connect the brine valve (5)
Open the salt lid
(4)
, remove the cap
(17)
, then
the brine valve
(5)
from its well
(16)
.
Set the fl oat height
(X)
, rod pulled, at the value
provided on your Scope of Delivery sheet.
Check that the brining tube
(9)
is cut straight on
its ends, put it on the sheath
(15)
, then tighten it
on the fi tting located on the brine valve foot
(18)
,
using the fl y nut
(19)
.
Put the brine valve
(5)
back into the bottom of the
well
(16)
, pass the brining tube
(9)
through the
hole of the cap
(17)
, then put this cap back upon
the well
(16)
.
Pass the brining tube
(9)
through the dedicated
hole in the salt tank, making sure that this tube
does not bend anywhere.
Connect the hydraulic block
Connect the brining tube
(9)
to the quick fi tting
(20)
.
Connect the in and out fl exible hoses
(13)
res-
pectively on the fl ange fi ttings
(21)
and
(22)
of
the hydraulic block.
Connect the drain tube
(8)
on the splined fi tting
(23)
and tighten it with a hose clamp (Serfl ex
type).
Connect the plug of the chlorination cell if your
softener has this option
(24)
.
Connect drain outlets.
Connect the drain tube
(8)
to the upper fi tting of
the siphon
(11)
and tighten it with a hose clamp
(Serfl ex type).
The siphon ensures the mandatory protection
of the domestic water circuit against sewage
backfl ow.
Connect the tube of the salt tank overfl ow
(10)
to the side fi tting of the siphon
(11)
, respecting a
slope of minimum 2% (2 cm per meter) from the
tank overfl ow to the siphon. Then tighten it with
a hose clamp (Serfl ex type).
The overfl ow must take benefi t of gravity and fol-
low a simple and short way. If not possible, install
a lift pump compatible with salted water.
Connect the siphon
(11)
to the drain by a rigid
PVC tube with a diameter of 40 mm, tightened
on the fi tting
(25)
.
15
9
17
16
18
19
co
te
«
X
»
9
21
22
23
24
20
8
25
10