Manual regeneration
At any time, it is possible to trigger the regeneration of the softener, via the long push (5 seconds)
on the
ê
R
key.
If this is done for
a test purpose, it is possible to manually go from one step to the next by briefl y
pushing the
ê
R
key.
Salt alarm acknowledgement
When no salt is left in the tank, the device displays the alternate words
SALT
and
CHECK
.
Once the salt refi ll is done, you may just wait for the next regeneration to let this alarm disappear. It
is recommended though to acknowledge immediately the alarm, following these steps:
•
Proceed with a long push (5 seconds) on the
Menu
key
•
Then briefl y push this
Menu
key to go through the menus until the display shows this one:
CHECK / SALT
(alternate)
On
•
Push once on
ê
R
or
é
key to make
Off
appear on the lower line
•
Push
Enter
to confi rm
•
Push
Menu
during 5 seconds to quit the menu: the alarm shall disappear
Power cut
In case of a power cut during a regeneration, this process restarts at the beginning of the ongoing
step. In case of a power cut during service, the softener will restart also in service.
Stand-by mode
It is possible to prevent the softener from going through a regeneration, automatic or manual. This
might be useful, for example, while you are waiting for the intervention of a technician in case of
technical problem. Therefore:
•
Proceed with a long push (5 seconds) on the
Menu
key
•
Then briefl y push this
Menu
key to go through the menus until the display shows this one:
STD-BY
Off
•
Push once on
ê
R
or
é
key to make
On
displayed on the lower line
•
Push
Enter
to confi rm
The display shows then the message
STD-BY
alternating with the softener autonomy value.
To cancel this function, you just have to come back to this
STAND-BY
menu and turn the lower line
into
Off
.
ADVANCED SETTING
Accessed by the code
23
, then the browsing works in the same way as the regular setting mode.
The intervention on the advanced setting shall be done by a trained professional. Any mistake can
disturb the work of the device and is under its author’s responsibility.