background image

11 

8.  Pre-mixer volume control 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Mic 1

Mic 2

Mic 3

Mic 4

Aux 1

Aux 3

Aux 2

Aux 4

Treble

Bass

Master

WMP-2100

A

B

C

H

G

F

E

D

Group

2

1

3

4

5

6

7

8

Mic 1

Mic 2

Mic 3

Mic 4

Aux 1

Aux 3

Aux 2

Aux 4

Treble

Bass

Master

Re-Start

Voice Level

Auto

Manual

Pass

30 SEC

Reset

Monitor Level

0

10

0

10

0

10

0

10

0

10

0

10

0

10

0

10

-10

+10

-10

+10

0

10

Microphone 

Mic 1 has priority for broadcasting 

Mic 2 

Mic 4 adjust Mic2~Mic4 

Aux 

Aux 1 adjust volume of 

phone broadcasting 

Aux 2 ~ Aux 3: adjust 

Aux2~Aux3 volume   

Bass: adjust bass volume 

Treble: adjust treble volume Master: 

adjust Master volume 

  Control microphone volume 

    a. Adjust Mic1~Mic4 volume 

    b. Mic 1 has priority for broadcasting 

    c. Mic 4: volume adjustment for Mic 4 (both front panel and rear panel).   

  Aux 1 is for adjusting phone broadcasting volume.    Aux 2~Aux 4 are for adjusting Aux2~Aux4 

volume. 

  Bass : adjust bass volume

Treble : adjust treble volume 

  Master

adjust Master volume 

Summary of Contents for DPS Series

Page 1: ...BXB Electronics Co Ltd 6F 1 No 288 5 Xinya Rd Qianzhen Dist Kaohsiung City 80673 Taiwan R O C TEL 886 7 9703838 FAX 886 7 9703883 www bxb tw DPS SERIES DIGITAL PA SYSTEM USER MANUAL ...

Page 2: ...ingle zone broadcasting 7 5 Group broadcasting 8 6 Reset groups 9 7 Monitor and Intercom function 10 8 Pre mixer volume control 11 9 Multi function operating 12 10 Identification and Solution for Remote Call back 13 11 Security Alarm 14 12 Scan remote status 15 13 Emergent Broadcasting backup system 16 14 Reset 16 15 Telephone broadcasting 17 16 Group broadcasting table 18 ...

Page 3: ...lume can be adjusted by Monitor Level knob 5 6 3Ø Microphone input Microphone volume can be adjusted by Mic4 volume control 6 Luminous volume meter 7 Scan Auto Automatically scan Remote Decoders Advanced operation buttons Scan Manual Manually scan Remote Decoders Pass All Call when decoders malfunction 1 2 3 4 5 6 7 9 8 WMP 2100 A B C H G F E D Group 2 1 3 4 5 6 7 8 Mic 1 Mic 2 Mic 3 Mic 4 Aux 1 A...

Page 4: ...tput sounds Monitor and Intercom buttons Intercom function 9 Mic1 Mic4 6 3 Ø Microphone volume knobs Mic1 has priority to broadcast Pre mixer volume control Aux1 Aux4 Adjust Aux1 Aux4 volume Aux1 is reserved for telephone broadcasting Master Adjust master volume Treble Adjust treble volume Bass Adjust bass volume ...

Page 5: ... 8 Mic 1 Mic 2 Mic 3 Mic 4 Aux 1 Aux 3 Aux 2 Aux 4 Treble Bass Master Re Start Voice Level Auto Manual Pass 30 SEC Reset Monitor Level 0 10 0 10 0 10 0 10 0 10 0 10 0 10 0 10 10 10 10 10 0 10 Operating red The main control unit detects signals automatically when pressing any broadcast buttons including single area all call etc The LED flashes red if they work properly In Use green The LED flashes ...

Page 6: ...tor Level 0 10 0 10 0 10 0 10 0 10 0 10 0 10 0 10 10 10 10 10 0 10 WMP 2100 A B C H G F E D Group 2 1 3 4 5 6 7 8 Mic 1 Mic 2 Mic 3 Mic 4 Aux 1 Aux 3 Aux 2 Aux 4 Treble Bass Master Re Start Voice Level Auto Manual Pass 30 SEC Reset Monitor Level 0 10 0 10 0 10 0 10 0 10 0 10 0 10 0 10 10 10 10 10 0 10 All zones broadcasting Clear selected zones 1 Press All Call red button to broadcast and all LEDs...

Page 7: ... will turn off when finish broadcasting 2 Done broadcasting Press All Clear Select one or more zones you want to broadcast You can start broadcasting when LEDs turn on and indicate orange Each button has a three colored LED light which shows different messages when lit the colors are as follows Green Groups or All Call broadcasting Orange Single zone broadcasting intercom calling status signal Red...

Page 8: ...reseted group button The LEDs will turn on and indicate green Press group button to finish and the LEDs will turn off 2 Press the group button again to finish broadcasting WMP 2100 supports 8 groups of group broadcasting and every Extension control unit supports 8 groups as well Therefore you can have 24 groups at most Please refer to instructions above for group setting The groups are named in al...

Page 9: ... the second time the LED will turn off shows the zone has been removed 3 Select the desired zones to add in Then press the group button for three seconds You will hear three long beeps The LEDs will turn on and indicate orange Groups broadcasting setting blue 4 Press All Clear to finish setting and all LEDs will turn off All LED will turn off There is no need to reset control unit when add remove ...

Page 10: ...d zone to enable Intercom is enabled when the LED turns on and indicates orange 2 Press the same zone again to disable intercom Intercom is disabled as LED turns off 1 Press and it will light up orange Select the desired zone to enable intercom and the green LED will be on simultaneously Press again to disable intercom and the light will be off Press to enable monitoring ex MIC CD Tape and it will...

Page 11: ...as priority for broadcasting Mic 2 Mic 4 adjust Mic2 Mic4 Aux Aux 1 adjust volume of phone broadcasting Aux 2 Aux 3 adjust Aux2 Aux3 volume Bass adjust bass volume Treble adjust treble volume Master adjust Master volume Control microphone volume a Adjust Mic1 Mic4 volume b Mic 1 has priority for broadcasting c Mic 4 volume adjustment for Mic 4 both front panel and rear panel Aux 1 is for adjusting...

Page 12: ...ra and light switching etc Instructions are shown as below Press All Clear for three seconds and the LEDs on 8 blue buttons will turn on Press All clear for three seconds 8 multi function buttons can be customized Select a zone and the LED will turn on and indicate orange After that press a multi function button to control Multi function are enabled when all LEDs turn on Select a desired zone to c...

Page 13: ...orange LED will stop flashing You can speak with remote person at this time Finish intercom as LED turns off 3 Press the same button to finish To provide request information of intercom call for help a return call signal is transmitted by remote decoder to main control unit The instruction as below 1 The remote decoder transmits a requested signal to main control unit as remote call button is pres...

Page 14: ...one Red LED will keep flashing while the beeps stop 3 Press the same zone again to cancel The alarm is canceled when LED turns off Remote zones are capable to be integrated with infrared modules or electronic magnetic locks to build sets of security alarms The instructions are shown as below 1 When any remote zone is broken in the remote decoder will transmit security signal to the main control un...

Page 15: ...ecurity system Permanent Green Remote security system is off remote lighting is off Flashing Red Remote Decoder is not installed not exist broken Permanent Orange Remote security system is on remote lighting is on Manual scan LED will turn on when enabled Meanwhile you will hear one long and five short beeps N C status of remote decoder will be shown when pressing any zone To cancel press Manual L...

Page 16: ... Auto Manual Pass 30 SEC Reset Monitor Level 0 10 0 10 0 10 0 10 0 10 0 10 0 10 0 10 10 10 10 10 0 10 Reset Press Pass LED will turn on to broadcast to all areas when main control unit malfunctions due to unknown reasons This function is to deal with malfunction result from being struck by lightning or other unknown reasons By pressing Pass you can broadcast to all Reset all setting to factory set...

Page 17: ...rocess is shown as below Telephone broadcasting table 1 Select available line from the PSTN public switched telephone network Dial designated line code on the phone As pressing the key which represents telephone broadcasting WMP 2100 will be turned on 2 Press the numbers of desired zones or group It s available from single zone group or all call Press key to clear incorrect code and re enter previ...

Page 18: ...3 4th Group 904 004 5th Group 905 005 6th Group 906 006 7th Group 907 007 8th Group 908 008 9th Group 909 009 10th Group 910 010 11th Group 911 011 12th Group 912 012 13th Group 913 013 14th Group 914 014 15th Group 915 015 16th Group 916 016 17th Group 917 017 18th Group 918 018 19th Group 919 019 20th Group 920 020 21st Group 921 021 22nd Group 922 022 23rd Group 923 023 24th Group 924 024 Notic...