background image

Safety Instructions 

1.

 

Please read the instruction manual carefully before installing and using the apparatus. 

2.

 

Please save the instruction manual well for reference. 

3.

 

Please follow the instructions and aware of warning indications. 

4.

 

Except your dealer, please do not use any spare part recommended by others.   

5.

 

Please use the fixing accessories provided by manufacturer. If the system is broken due to improper fixing, the manufacturer 

would not bear the responsibility for compensation.   

6.

 

Please make sure the power cord has been fixed properly. 

7.

 

Do not use any three-hole plug or extension cord as this can result in the risk of fire or short circuit.   

8.

 

Do not stuff anything into the apparatus or splash any liquid on it. 

9.

 

Please contact maintenance technician if the conditions listed below occur: 

A.

 

Power cord or plug is damaged. 

B.

 

Liquid has been spilled into the apparatus. 

C.

 

The system cannot operate normally even everything follows the instructions. 

D.

 

The apparatus drops or is damaged with cover. 

E.

 

Not all functions work. 

10.

 

To reduce the risk of damage caused by lightning strike, it is essential that all cables must be bonded well to the same   

grounding point.   

11.

 

Install the conference main control unit and its other equipment carefully. Impacting and fierce shaking should be avoided. 

12.

 

Do not disassemble or remodel the main control unit: 

A.

 

High voltage and sensitive electrical circuit are inside of the apparatus. Do not disassemble it to prevent electric shock. If       

the disassembling is required, please ask a qualified technician for help. 

B.

 

The specification of any replaced spare part should be validated by manufacturer, or it may cause fire and short circuit.     

13.

 

Do not block the ventilation opening to prevent overheating and malfunction. 

14.

 

Do not use the apparatus in the environment with improper temperature, moisture, and power level: the adequate range   

is 0°C ~ 40°C (32°F ~ 104°F) and 90% below of moisture. 

15.

 

Do not expose the apparatus to rain and moisture: Please put it in a dry location to avoid any damage of components. 

16.

 

Do not clean the apparatus and its accessories with chemical detergent. Use a cloth dampened a little bit water instead. 

17.

 

Do not switch on/off the power of apparatus rapidly: Rapid switch on/off should be avoided all the time to ensure the   

regular operation of the sensitive electronic circuit. 

18.

 

Caution: The static electricity treatment of printed circuit boards should follow ESD safety measure. 

19.

 

Caution: Please select the accurate power plug and aware of the voltage accordance with that in your country to prevent   

any damage.   

 

Warning: Only qualified maintenance technicians can disassemble the cover of apparatus. Please unplug before taking apart the 

cover; switching on the power is not allowed if the cover has not been assembled back.

 

Summary of Contents for FCS 6350

Page 1: ...FCS 6300 Instruction Manual ...

Page 2: ...on 5 Talking Mic 5 Mode 5 Open Mic QTY 6 Auto Off 6 Advanced Menu 6 Speed Dome Set 7 Dome Mode 7 Video Switch Video SW 7 Go back to Home Point Dome HGO 7 Mic Position 7 Set Preset 8 Go Preset 8 Volume Set 8 Mic Checking 8 Mic ID Set 8 Voice Set 9 Language 9 IP Address 9 Reset Settings 9 Interface of Web Page Control 10 Log In 10 Speaking 10 Conference Setting 11 Operating Mode 11 Open Mic QTY 12 M...

Page 3: ...2 Dome Mode 14 Video Override 15 Go Home Perset 15 Set Preset 16 ...

Page 4: ...ntrol unit possesses the mechanism of password protection preventing unauthorized users logging in the system 5 Audio recording and playing are provided 6 Plug and play USB Interface for Recording The sampling frequency of 16 bit or more 8 11 025 16 22 05 32 44 1 and 48KHz is provided 7 Equipped with a graphical LCD screen to display the current status of the system 8 Matrix Zone Selection Termina...

Page 5: ...ided 12 Do not disassemble or remodel the main control unit A High voltage and sensitive electrical circuit are inside of the apparatus Do not disassemble it to prevent electric shock If the disassembling is required please ask a qualified technician for help B The specification of any replaced spare part should be validated by manufacturer or it may cause fire and short circuit 13 Do not block th...

Page 6: ...pper items listed in the setting menu 4 Menu setting control LIFT This is for selecting setting the left items listed in the setting menu 5 Menu setting control RIGHT This is for selecting setting the right items listed in the setting menu 6 Menu setting control DOWN This is for selecting the lower items listed in the setting menu 7 ESC Press to go back to the previous menu 8 Enter Press to select...

Page 7: ...dome camera To control other brands cameras just connect this port with BXB C901 s RS 485 Receiver Port 5 RJ 45 Input for Conference Microphone Unit 4 individual links for microphone units 6 RJ 45 Audio Output 4 individual audio outputs without mixing through the main control unit 7 AUXOUT RCA jack AUX balanced output 8 MIC modular input terminal ψ6 3mm 1 XLR balanced connector 1 9 Aux 1 Input RCA...

Page 8: ...Enter to display the ID of the talking microphone Press Enter again to turn off the selected talking microphone If all microphones are off the screen will show NO MIC Chairman microphone ID 01 10 Delegate microphone ID 001 999 Mode Press Left Right button to choose a conference mode ...

Page 9: ...the request via microphone unit main control unit and graphical control software FIFO First In First Out Under certain Open Mic Qty delegates talk in order For example if Open Mic Qty is one the second delegate should wait until the first one finishes talking Meanwhile the indicator ring of second delegate microphone is red and flashing In the same condition if more than 3 delegates press TALK but...

Page 10: ...ft Right button to turn on off the function for going back to the home preset point When there is no one speaking in the conference turning on this function will make the camera take the image of the preset home point automatically DOME and ADR can be set as HOME Mic Position Total of 16 cameras can be operated simultaneously to track the image of each microphone unit Each camera has 128 preset po...

Page 11: ...fy if the setting of microphone s preset point is correct as well as check if the connection between main control unit and camera is usual If the connection is failed the message dome does not exist or timeout will be shown Volume Set System 20 50 Aux In 20 50 Mic In 20 50 Press Left Right button to adjust the volume The maximum volume can reach 50 Mic Checking Test the system is able to detect th...

Page 12: ...tion If it is on the microphone will turn on automatically as it senses the speaker s voice Language Press Left Right button to select a language Two languages are provided Chinese and English IP Address IP Internet Protocol Address after connecting with a router AP the main control unit will automatically display the IP address configured from DHCP IP 192 168 1 X X If it is not configured from DH...

Page 13: ...10 Interface of Web Page Control Log In Default user ID admin Default password 00000 five zeros Speaking Request for Speaking Mic Turn Off the Speaking Mic Refuse Allow to Speak Speaking Mic Status ...

Page 14: ...unit main control unit and graphical control software 3 Override Under certain Open Mic Qty delegates take turn speaking Setting Open Mic Qty as three when the forth microphone is on the first one will be off when the fifth microphone is on the second one will be off However chairman is always unrestricted 4 FIFO Under certain Open Mic Qty delegates talk in order For instance after the first deleg...

Page 15: ...ultaneously Chairman microphone is always unrestricted Under Normal Mode press 0 to set All Mic all microphones can be turned on randomly Under Chairman Mode Open Mic Qty will switch to REQUEST The quantity of open microphone cannot be set in this mode ...

Page 16: ... Delegates still can press TALK button to turn on the microphone by themselves Chairman microphone is always unrestricted Invalid Delegate microphones should be turned off manually by pressing TALK button Volume The volume of system s microphones Aux in and other microphones can be adjusted within 50 levels ...

Page 17: ...ore than one speakers press TALK button the camera taking will stay at the last speaker who finishes talking Other speakers should press TALK button again to make the camera track their images back Sound In this mode the main control unit can automatically detect the position of the speaker who is talking and then transmit the signal to the camera to do image tracking Off Not operating image track...

Page 18: ... be equipped to control multiple cameras and output the images Go Home Preset Select turning On or Off of going back to Home preset point When there is no one speaking in the conference turning on this function will make the camera take the image of the preset home point automatically ...

Page 19: ...XB s high speed dome camera possesses 128 preset points One main control unit is able to control 16 cameras 1 Select the preset point of camera 3 Select camera s ID number 2 Save the setting 4 Select microphone s ID number ...

Reviews: