background image

 

 

Warning

 

1.

 

For maintenance and installation, please refer to the chart above.   

2.

 

Every wire has its 

unique

 function so please make sure the wiring is correct 

before turning on the unit. Otherwise, incorrect wiring might cause damage to 
it. (Please refer to Quick Check Installations). 

3.

 

To prevent damage, please use wires attached with WMP 2100 only.   

 

 

Summary of Contents for WMP-2100

Page 1: ...Di ig gi it ta al l P PA A s sy ys st te em m I In ns st ta al ll la at ti io on n G Gu ui id de e V V Ve e er r rs s si iio o on n n 1 1 1 2 2 2 D D Da a at t te e e A A Au u ug g gu u us s st t t 1 1 16 6 6 2 2 20 0 01 1 11 1 1 ...

Page 2: ...brating buzzer 10 5 Positions and setting of broadcast DIP switches 11 a WMP 60 DIP switch setting 12 b WMP 60 200 zones DIP switch chart 13 III Linked control for two main console s WMP 2100 14 IV Connection for extension control device WMP 2100A 15 V Connection for Graphical Control Software 16 VI Connection for Telephone broadcasting system 17 VII External activated port and installation 18 VII...

Page 3: ...damage from lightning strikes it is important that all electric cables should be bonded to the same grounding point 7 Do not block any ventilation openings to prevent overheating and malfunction 8 Do not expose the apparatus to rain or moisture Humidity may lead inside components to damage Appropriate shelter is necessary when placing it outside Best working environment Temperature 0 C 40 C 32 F 1...

Page 4: ...static treatment correct ESD safety precaution and grounding should be assured 13 Note Before connecting the apparatus to main AC please select the supply voltage in accordance with the wall voltage in your country to prevent damage Refer to Installation and Setting Page 8 for selecting 14 Warning Do not disassemble or remodel the product as these actions may lead to electrical shock or damage The...

Page 5: ...r telephone broadcast System installers select an available line from the PBX private branch exchange to connect After connected you are able to broadcast via remote telephones Telephone broadcasting interface VOICE Telephone broadcast volume knob CHIME Chime volume knob 5 Area Remote ALL CALL COM Enable ALL CALL can be used with timer clock External trigger To activate enforced control connectors...

Page 6: ...tor Main Control Connector for main cable WMP 7c B OUT Red DC 24V power connector for remote decoder WMP 60 G Black Common ground for remote decoder WMP 60 control signal RF IN Blue Signal input from decoders main console connector I T Purple Connector for intercom signal 8 Link Connector for other main console s 9 PC Data RS 232 interface for BXB graphical control software 10 EXPAND Connector for...

Page 7: ...und wire signal cable Blue RF IN KEY Return signal cable For example N O N C and self detect Purple INTERCOM Intercom signal cable need connect the signal wiper and ground wire to control signal Green COM Power amplifier output AUX No cathode or anode No different White 100V Power amplifier output AUX No cathode or anode No different GND RF OUT I T AMP COM B DC 24V RF OUT POWER AMPLIFIER POWER AC ...

Page 8: ... above 2 Every wire has its unique function so please make sure the wiring is correct before turning on the unit Otherwise incorrect wiring might cause damage to it Please refer to Quick Check Installations 3 To prevent damage please use wires attached with WMP 2100 only ...

Page 9: ...as the way above Fig 2 Connection instructions for WMP 7c and BXB speaker Build in decoder GND RF OUT I T AMP COM B DC 24V RF OUT AMP 1 00V 黃色 紅色 黑色 藍色 紫色 綠色 白色 GND RF OUT I T AMP COM B DC 24V RF OUT AMP 1 00V 黃色 紅色 黑色 藍色 紫色 綠色 白色 1 00V COM GND RF OUT I T AMP COM B DC 24V RF OUT AMP 1 00V 黃色 紅色 黑色 藍色 紫色 綠色 白色 GND RF OUT I T AMP COM B DC 24V RF OUT AMP 1 00V 黃色 紅色 黑色 藍色 紫色 綠色 白色 GND RF OUT I T AMP ...

Page 10: ...ide Note The connection applies to any kind of high speakers Chart 3 1 Parallel connection and color management is applied Simply connect green to green white to white blue to blue red to red etc 2 Users are able to connect external speakers ceiling speakers horn speakers etc simply connect both red and black wires Fig 4 to the speaker s output autotransformer there is no difference between cathod...

Page 11: ...o Fig 4 for connection instructions 4 WMP 60 Remote Decoder is used with BXB WS 335T vibrating buzzer OUT B G IN COM ID S W 5 ON 2 3 4 1 7 8 6 G 100V RF RF alarm speaker BXB WS 335T Call back trigger signal GND Access control security trigger signaltrigger signal Lift call back signal contact Fig 4 Remote Decoder is used with BXB amplifier teaching speaker WS 817AL WS 665A Flash Alarm Fig 5 Remote...

Page 12: ...change broadcasting zone from the back of BXB speaker or on remote decoder WMP 60 Where you can find it WMP 60 Remote Decoder Amplifier Teaching Speakers WS 665Am 60D WS 817ALM 60D Box Speakers WS 665T 60D WS 817TL 60D BXB Speakers with built in decoder WMP 60D ...

Page 13: ...age are interpreted as one number Definition GP Group code To set Group 1 8 all ON is 7 all OFF is 8 Example 1 Code 305 Group 3 and area 5 GP 03 DIP switch 6 7 are ON 8 is OFF CH 05 DIP switch 1 3 are ON 2 4 5 are OFF Example 2 Code 812 Group 8 and area 12 GP 08 DIP switch 6 7 8 are OFF CH 12 DIP switch 3 4 are ON 1 2 5 are OFF ...

Page 14: ...13 b WMP 60 200 zones DIP switch chart ...

Page 15: ...MP 2100 s Fig 6 and work mutually 2 A 9 core control cable and a 2 core audio source cable are essential 3 Distance between two consoles should be less than 1km 0 6 mile If the length exceeds please contact BXB Electronics for further assistance Fig 6 connecting instructions for multiple WMP 2100s ...

Page 16: ...pports 192 broadcast zones at most 2 Every console has 8 memorable control group buttons which means included 2 extension control devices there are 24 group buttons at most 3 If there are more than 192 zones users can install another main console WMP 2100 for extension 4 Please refer to Figure 7 for connection instructions Fig 7 WMP 2100A Connection ...

Page 17: ... 3 Simply complete setup by connecting RS 232 on PC Server 4 The system can be controlled through Internet Intranet Control software should be installed on remote computer 5 By installing Control Software on remote computers you can also control the system via the Internet Intranet Wireless Lane INTERNET COM 1 Fig 8 Connection between Graphical Control Software and WMP 2100 RS 232 Cable ...

Page 18: ...technician or your service provider to limit certain extensions for broadcasting 3 Output volume might vary from different PBXs chime and broadcasting volume can be adjusted separately from rear panel Adjust the two knobs when installing and adjust AUX1 from front panel in the future PBX Rotary volume control for Chime Rotary volume control for Phone Broadcasting Connector plug for telephone Fig 9...

Page 19: ...to Group 8 3 Connection for timer clock Please refer to sound source input instructions for timer clock audio source connection to complete installation BXB also provides digital multi function music timer clock on PA Control Software There are 24 groups of regular broadcasting 8 groups of unlimited setting mix random track playing mode etc You can even broadcast through the Internet by it Please ...

Page 20: ...input on the front panel work in parallel Thus if both of them are used at the same time the gain for them will be attenuated In that case turn up the volume MIC 4 on the front panel to balance 2 External Aux input a AUX 1 should be reserved for telephone broadcasting only b AUX2 AUX4 are for CD player tapes recorder radio MP3 player and other external equipments 3 External Aux output a AUX Output...

Page 21: ...circuited VTVM Vacuum Tube volt Meter Measuring whether the high pressure signal wires are short circuited Cross inspecting among control signal lines high pressure signal lines and control lines interaction checking 1 Main control cables WP 7C should be checked by colors RF OUT Yellow B Red RF IN Blue G Black If intercom function is activated please inspect INTERCOM purple signal cable as well 2 ...

Page 22: ...ositive and negative impedance values are high above 500Ω unless there are any short circuits If that happens use 1 2 troubleshooting method to examine Connect the cables to WMP 2100 after examining After examining turn on WMP 2100 and it will start auto scanning Make sure all the decoders work properly then connect high pressure signal lines to a power amplifier If more than two main consoles are...

Page 23: ...22 X System Structure ...

Reviews: