7
MODE
POWER
BUTTON
LED
LCD DISPLAY
DESCRIPTION
AUDIO
Battery Mode
On
1. Estimated time
2. Output voltage
3. Output frequency
4. Load percent
5. Input voltage
6. Input frequency
7. Battery level
Press
button
to cycle through the
displayed information.
Beeping every 10 seconds
Low Battery Alarm
On
indicator is
flashing every second
Beeping every second
Battery Mode with
Overload Alarm
On
indicator is
flashing every second
Beeping every 0.5 seconds
Battery Mode in
Mute
On
indicator will
display
The UPS will not sound an
alarm until after an event
occurs, such as low battery,
overload, etc.
Output Short
Circuited
On
Disconnect short-
circuited loads and
restart the UPS
Continuously beeping
Overload Fault
On
Turn off the UPS.
Disconnect all loads
and restart the UPS.
Plug in equipment one
at a time and make
sure not to exceed the
UPS rating for load
capacity.
Continuously beeping
Battery Mode Output
High Fault
On
Call for service
immediately
Continuously beeping
Overcharge Fault
On
Call for service
immediately
Continuously beeping