NÜO Flux Manual
Information
Features
4
TECHNICAL SPECIFICATIONS
NÜO FLUX:
INPUT VOLTAGE
24VDC (11 - 28 VDC)
POWER
1.8 W
CPU
32-bit ARM Microprocessor
READING DISTANCE
5 - 8 cm
MAXIMUM POWER
250 mA
COMMUNICATIONS
2 twisted pairs.
Baud rate: 38400
Protocol: High security communications
CONNECTION
60 cm of 5 mm diameter cable with 6 wires is provided
INPUTS
1 Door sensor input (Detection resistance: <20 Ω)
OUTPUTS
1 lock control output with 24 VDC power supply (250 mA maximum)
ALARM
2 sound levels incorporated for granted access and denied access
ILLUMINATION
Automatically regulated according to environmental conditions.
Colours according to status:
-
Red/White: Terminal offline.
-
Degraded Red/Pink: Terminal in card enrolment mode.
-
Flashing blue: Terminal in firmware update mode.
-
Blue: Terminal on standby.
-
Green: Access granted.
-
Red: Access denied.
-
White: Card writing operation.
MATERIALS
Manufactured with the highest quality polycarbonate with scratch-resistant
unbreakable glass polycarbonate facing
INSTALLATION
Flush installation for indoor or outdoor use
PROTECTION LEVEL
IP65
OPERATING
TEMPERATURE
-20 °C to 50 °C