background image

BYAN SYSTEMS, INC. 

Automated Gate and Access Control Products 

 

 

413 Linden • Lusk, WY 82225 • (800) 223-2926 

 

16

 

DIP SWITCH ASSEMBLY OPERATION MODE SELECTION; 

No. 

OPTION ON 

OFF 

REVERSING STROKE FUNCTION 

(OPERATOR FIRST WILL CLOSE FOR 1 SECOND)

 

ACTIVE INACTIVE 

2 STEP-BY-STEP 

FUNCTION* 

ACTIVE  INACTIVE 

3 AUTOMATIC 

CLOSING 

FUNCTION 

ACTIVE  INACTIVE 

REVERSING BUTTON IS NOT 
OPERATIVE DURING OPENING 

ACTIVE INACTIVE 

CLOSING ORDER BY CARS SAFETY CONTACT  ACTIVE 

INACTIVE 

SEE NOTE BELOW REF JP1 

--------------  -------------- 

CARS SAFETY CONTACT IS  
OPERATIVE DURING OPENING 

ACTIVE  

INACTIVE 

 

*STEP-BY-STEP IS THAT EACH ACTIVATION OF THE REVERSE BUTTON WILL STOP THE 
GATE BEFORE CHANGING DIRECTION. 
 

NOTE: THERE IS A JUMPER JP1 (BELOW THE REMOTE CONTROL CARD 
CONNECTOR) THAT CAUSES THE SELECTABLE OPTION No. 6 IN THE FOLLOWING 
MANNER: 
 
JP1 OPEN: 
No. 6 

ON

 

IN THE POWER ON STATE, UNIT WILL DO A CLOSING 
FUNCTION

OFF

  IN THE POWER ON STATE, UNIT WILL DO AN OPENING  

FUNCTION. 

 
JP1 CLOSED: 
 

 

IN THE POWER ON STATE, THE DOOR REMAINS PAUSED.  IN  

 

 

THIS CASE, THE SWITCH No. 6 CONTROLS THE FUNCTION OF  
THE TRAFFIC LIGHTS. 

 

ON

 

THE TRAFFIC LIGHTS CARD WILL ACT AS A FLASHING LIGHT 

 

 

CARD (UPPER RELAY) AND A GARAGE LIGHT CARD (LOWER 

  RELAY). 
 

OFF

  THE TRAFFIC LIGHTS CARD WILL ACT AS GREEN AND RED  

  LIGHTS. 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 600A

Page 1: ... EQUIPMENT THAT SHOULD BE INSTALLED ON EACH JOB SITE THIS IS IN ACCORDANCE WITH YOUR LEGAL LIABILITY TO YOUR CUSTOMER ENSURE THAT THE PROTECTION AND WARNING SIGNALING DEVICES ARE OPERATIONAL AND VISIBLE THESE STEPS WILL AID IN YOUR DEFENSE SHOULD YOU BECOME INVOLVED IN LITIGATION REGARDING INJURY OR DAMAGE ATTENTION ALL INSTALLERS EXPERIENCED OR NOT PLEASE REVIEW PAGES 4 AND 10 BEFORE YOU INSTALL ...

Page 2: ...E YOU INSTALL 4 DURING INSTALLATION PROCEDURES 4 INSTALLATION COMPLETION FOLLOW UP 5 INSTALLING THE OPERATOR 6 PRESSURE ADJUSTMENTS 7 PURGING THE OPERATOR 7 HYDRAULIC FLUID 8 MOUNTING GEOMETRY 10 FRONT MOUNTING DETAIL 10 MOUNTING BRACKET LOCATION 11 MANUAL BYPASS 12 WIRING THE CONTROL AND ACCESSORIES 13 CONNECTING THE OPERATOR 19 LOOP CONNECTORS 21 WARRANTY 26 END USER SAFETY HANDOUT 27 CUSTOMER A...

Page 3: ...OUSING UNIT FIVE OR MORE SINGLE FAMILY UNITS HOTEL GARAGES RETAIL STORES OR OTHER BUILDING SERVICING THE GENERAL PUBLIC CLASS III INDUSTRIAL LIMITED ACCESS VEHICULAR GATE OPERATOR A VEHICULAR GATE OPERATOR OR SYSTEM INTENDED FOR USE IN AN INDUSTRIAL LOCATION OR BUILDING SUCH AS A FACTORY OR LOADING DOCK AREA OR OTHER LOCATION NOT INTENDED TO SERVICE THE GENERAL PUBLIC CLASS IV RESTRICTED ACCESS VE...

Page 4: ...S BRACKET AND SWIVEL JOIN INSTALLED 39 3 4 INCHES OPERATOR WIDTH 3 3 8 X 3 3 8 INCHES OPERATOR HEIGHT 4 5 16 WITH LOCK OPERATOR SPEED TO 90 DEGREES 12 SEC PISTON STROKE 250 MM OR 9 7 8 INCHES AMBIENT OPERATOR TEMPERATURE RANGE 60 TO 220 DEGREES F HYDRAULIC FLUID SHELL TELLUS T 15 THIS PATENTED NEW CONCEPT IN LINEAR ACTUATOR DESIGN ELIMINATES THE NEED FOR PHYSICAL STOPS THE VALVE DESIGN CUSHIONS TH...

Page 5: ...R LEGS TO PASS THROUGH IS A POTENTIAL HAZARD RECOMMEND AND PROVIDE SAFE GUARDS AGAINST THESE HAZARDS 6 REMOVE THE END USER SAFETY ADVISORY HANDOUT FROM THIS MANUAL REQUEST THE END USER REVIEW THE MATERIAL AND SIGN IT COLLECT THE HANDOUT WHEN THE JOB IS COMPLETE DURING INSTALLATION 1 LOCATE THE ELECTRONIC CONTROLS FAR ENOUGH FROM THE GATE SO THE END USER CAN OBSERVE BUT NOT TOUCH THE GATE WHILE OPE...

Page 6: ...HE MANUAL BYPASS POSITION THE GATE LEAF AT 45 DEGREES PRESS THE TEST BUTTON ON THE G2M CONTROL BOARD THE FIRST SIGNAL WILL ALWAYS BE TO OPEN IF THE OPERATOR RUNS TO THE CLOSED POSITION TURN OFF THE COMMERCIAL POWER AND REVERSE THE MOTOR CONNECTIONS ON PINS 1 AND 3 5 OPERATE THE ACTUATOR SEVERAL TIMES UNTIL YOU CAN DETECT A RISE IN THE FLUID TEMPERATURE THIS CAN BE DONE BY PLACING YOUR HAND ON THE ...

Page 7: ...E OPERATOR AND USING THE MOTOR TO EXTEND THE PISTON PRODUCING 9 7 8 OF PISTON IT IS VERY IMPORTANT WITH THE 600A THAT THE PISTON BOTTOMS OUT IN BOTH DIRECTIONS 6 SCREW THE I BOLT INTO THE END OF THE PISTON TO OF THE LENGTH OF THE THREADS ATTACH THE FRONT BRACKET TO THE OPERATOR 7 ATTACH THE OPERATOR TO THE REAR MOUNTING BRACKET 8 WITH THE GATE IN THE FULL CLOSED POSITION LEVEL THE OPERATOR AND SCR...

Page 8: ...EN REMOVE THE FILL CAP TO EXPEL ANY AIR IN THE OPERATOR REPLACE THE OIL FILLER CAP SCREW AND TIGHTEN ONLY SNUG ADJUSTING THE OPERATOR THE PRESSURES ON THE OPERATOR ARE PRESET AT BYAN SYSTEMS PRIOR TO SHIPMENT IF THE PRESSURES DO NEED TO BE ADJUSTED WHETHER HIGHER OR LOWER YOU MUST ADJUST BOTH DIRECTIONS THE SAME NUMBER OF TURNS i e TURN TURN ETC THE PRESSURE ADJUSTMENT SCREW ARE FOUND UNDER THE LO...

Page 9: ... PREMATURE REPLACEMENT IT HELPS PREVENT CORROSION TO METALS AND IS DESIGNED TO BE COMPATIBLE WITH HOSES SEALS AND OTHER ELASTOMER PRODUCTS TELLUS T 15 READILY SEPARATES AIR AND WATER TO PREVENT FOAMING KEEPING THE FLUID FIT AND DIELECTRIC STRENGTH HIGH WHERE TO BUY SHELL TELLUS FLUIDS AT YOUR NEAREST SHELL DISTRIBUTOR BYAN SYSTEMS DISTRIBUTOR OR AT BYAN SYSTEMS WAREHOUSE FLUID AND YOUR OPERATOR TH...

Page 10: ...BYAN SYSTEMS INC Automated Gate and Access Control Products 413 Linden Lusk WY 82225 800 223 2926 9 ...

Page 11: ...BYAN SYSTEMS INC Automated Gate and Access Control Products 413 Linden Lusk WY 82225 800 223 2926 10 ...

Page 12: ... 80 5 3 4 4 3 4 3 1 2 85 5 1 2 4 1 2 3 1 2 90 5 1 8 4 1 2 2 3 4 95 4 3 4 4 1 2 2 3 4 100 4 3 8 4 1 2 2 3 4 105 3 1 4 5 1 8 2 3 4 110 3 1 8 5 2 3 4 NOTE THE MINIMUM DISTANCE FROM THE REAR POST FACE TO THE REAR MOUNTING BRACKET IS 1 3 4 OUTWARD SWING DEGREE A B C 70 6 3 4 4 3 4 3 1 4 75 6 1 4 4 3 4 3 1 4 80 6 4 3 8 3 1 4 85 5 1 2 4 1 2 3 90 4 7 8 4 3 4 3 95 4 1 2 4 3 4 2 3 4 100 4 3 4 4 1 4 2 3 4 10...

Page 13: ... THE OPERATOR IN THE EVENT OF A POWER FAILURE OR MALFUNCTION IT IS LOCATED UNDER THE KEYED CAP ON TOP OF THE OPERATOR A METRIC ALLEN WRENCH IS SUPPLIED IN THE CAP TO RELEASE THE BYPASS VALVE TURN THE VALVE COUNTER CLOCKWISE UNTIL THE OPERATOR RELEASES WHEN TIGHTENING THE BYPASS VALVE IT MUST BE TIGHT IN ORDER TO PREVENT FLUID OR PRESSURE ESCAPING BACK INTO THE CHAMBER ...

Page 14: ...GE A C 18 AWG TO 100 FEET 16 AWG TO 170 FEET 14 AWG TO 270 FEET 12 AWG TO 430 FEET 10 AWG TO 690 FEET 8 AWG TO 1100 FEET LOW VOLTAGE D C 20 AWG TO 400 FEET 18 AWG TO 700 FEET 16 AWG TO 1100 FEET 14 AWG TO 1700 FEET 12 AWG TO 2800 FEET 10 AWG TO 4500 FEET NOTE THESE WIRE SIZES ARE ONLY GENERAL RECOMMENDATIONS FEDERAL STATE AND LOCAL CODES ALWAYS TAKE PRECEDENCE CONSULT THE N E C OR LOCAL AUTHORITY ...

Page 15: ...TCHES CAN SELECT SOME DIFFERENT OPTIONS OF THE CONTROL UNIT THERE ARE THREE POSSIBLE TIMING POTENTIOMETERS OPENING TIME AUTOMATIC CLOSING TIME AND THE CLOSING TIME A DIP SWITCH CAN DOUBLE THE OPENING AND CLOSING TIME CHARACTERISTICS BUTTONS REVERSING BUTTON THE FIRST ACTIVATION WILL MAKE THE GATE OPERATE THE SECOND ACTIVATION WILL MAKE THE GATE STOP THE THIRD ACTIVATION WILL REVERSE THE GATES DIRE...

Page 16: ...IME NOTE BUILT IN 2 SEC TIMER TO STOP GATE BEFORE REVERSING OPERATION OCCURS OPEN CLOSE LIMIT SWITCHES THEY STOP THE OPENING AND OR CLOSING OPERATION MUST REMOVE THE TWO JUMPER WIRES FROM TERMINAL 11 TO 12 AND 13 IF USED ENTRAPMENT SAFETY CONTACT IF ACTIVATED THE RESULT IS REVERSING THE MOVEMENT IN BOTH OPENING AND CLOSING FOR 2 SECONDS THEN STOPS IF THE SAFETY CONTACT IS STILL ACTIVE THE ALARM WI...

Page 17: ...OPERATIVE DURING OPENING ACTIVE INACTIVE STEP BY STEP IS THAT EACH ACTIVATION OF THE REVERSE BUTTON WILL STOP THE GATE BEFORE CHANGING DIRECTION NOTE THERE IS A JUMPER JP1 BELOW THE REMOTE CONTROL CARD CONNECTOR THAT CAUSES THE SELECTABLE OPTION No 6 IN THE FOLLOWING MANNER JP1 OPEN No 6 ON IN THE POWER ON STATE UNIT WILL DO A CLOSING FUNCTION OFF IN THE POWER ON STATE UNIT WILL DO AN OPENING FUNC...

Page 18: ...LY 2 POWER SUPPLY 3 OPEN MOTOR 1 4 CLOSE MOTOR 1 5 COMMON MOTOR 1 6 OPEN MOTOR 2 7 CLOSE MOTOR 2 8 COMMON MOTOR 2 ACCESSORY TERMINALS FROM LEFT TO RIGHT ARE AS FOLLOWS 1 OUTPUT PEOPLE OR ANIMALS ALARM CONTACT N O 2 OUTPUT PEOPLE OR ANIMALS ALARM CONTACT N O 3 24V AC 1 AMP MAX COMMON 4 24V AC 1 AMP MAX POWER 5 OUTPUT ELECTRIC LOCK 12VDC 1 AMP MAX 6 OUTPUT ELECTRIC LOCK 12VDC 1 AMP MAX 7 INPUT RESET...

Page 19: ...OUTPUT 1 AMP MAX 4 24VAC OUTPUT 1 AMP MAX 5 ELECTRIC LOCK RELEASE 12VDC 6 ELECTRIC LOCK RELEASE 12VDC 7 ENTRAPMENT ALARM RESET 8 ENTRAPMENT SAFETY CONTACT 9 COMMON TO SAFETY CONTACT 10 REVERSING SAFETY CONTACT 11 COMMON TO LIMIT SWITCH 12 CLOSE LIMIT SWITCH 13 OPEN LIMIT SWITCH 14 STOP BUTTON 15 COMMON TO STOP BUTTON 16 COMMON TO CONTROL CONTACT 17 CLOSE COMMAND 18 OPEN COMMAND 19 REVERSE COMMAND ...

Page 20: ...TION TERMINAL DESCRIPTION 1 COMMERCIAL POWER SUPPLY 115V NEUTRAL WHITE 220V LINE BLACK 2 COMMERCIAL POWER SUPPLY 115V LINE BLACK 220V LINE RED 3 MOTOR 1 CLOSE DIRECTIONAL BLACK 4 MOTOR 1 OPEN DIRECTIONAL BLACK 5 MOTOR 1 COMMON WHITE 6 MOTOR 2 CLOSE DIRECTIONAL BLACK 7 MOTOR 2 OPEN DIRECTIONAL RED 8 MOTOR 2 COMMON WHITE ...

Page 21: ...T COUPLED TO PREVENT MALFUNCTION DUE TO INTERFERENCE OR ATMOSPHERIC DISTURBANCES THE CONTROL UNIT POWERS THE CARD THE CARD HAS TO BE INSERTED IN THE CONNECTOR MARKED AS T 2 MOTOR ON THE MAIN BOARD OF THE CONTROL UNIT IN THE OPENING OPERATION MOTOR 1 ACTS FIRST AND IN THE CLOSING OPERATION MOTOR 2 ACTS FIRST ADJUSTABLE TIMERS DESCRIPTION MINIMUM MAXIMUM LEFT MOTOR 1 0 SECONDS 15 SECONDS RIGHT MOTOR...

Page 22: ...THE INSULATION WHICH RESULTS IN EXCESSIVE LOOP FREQUENCY DRIFT YOU MUST CHOOSE A WIRE WITH AN INSULATION THAT IS MOST IMPERVIOUS TO MOISTURE IT IS ALSO IMPORTANT TO CHOOSE A WIRE WITH A RUGGED ABRASION RESISTANT INSULATION REMEMBER THAT ALL PAVEMENTS ARE POROUS AND CONTAIN TRAPPED MOISTURE WATER OR OTHER CHEMICALS WILL EVENTUALLY REACH THE INSULATION AND EITHER ATTACK THE INSULATION BE ABSORBED BY...

Page 23: ...LLENT PROTECTION FOR WIRE USED IN SAW CUT LOOP INSTALLATIONS BOTH TYPES ARE ABRASION RESISTANT MUCH HARDER NOT IMPOSSIBLE TO STRIP AND VERY MOISTURE RESISTANT SUMMARY THE USE OF THE CORRECT TYPE OF WIRE FOR THE JOB AS WELL AS THE PROPER INSTALLATION TECHNIQUES WILL AVOID FREQUENT SERVICE CALLS BEGINNING SOON AFTER INSTALLATION AND RESULT IN YEARS OF TROUBLE FREE SERVICE AND IN SATISFIED CUSTOMERS ...

Page 24: ...BYAN SYSTEMS INC Automated Gate and Access Control Products 413 Linden Lusk WY 82225 800 223 2926 23 ...

Page 25: ...BYAN SYSTEMS INC Automated Gate and Access Control Products 413 Linden Lusk WY 82225 800 223 2926 24 ...

Page 26: ...BYAN SYSTEMS INC Automated Gate and Access Control Products 413 Linden Lusk WY 82225 800 223 2926 25 ...

Page 27: ...e and extent of the dealer s warranty if any There are no obligations or liabilities on the part of Byan Systems Inc for consequential damages arising out of or in connection with the use or performance of these products or other indirect damages with respect to loss of property revenue or profit cost of removal original installation or reinstallation Warranty will be considered void if damage or ...

Page 28: ...SSURANCE OF SAFETY RESTS WITH THE USER OF THE GATE SYSTEM AT ANY PARTICULAR TIME GATE SYSTEMS SHOULD BE PROTECTED AS MAY BE NECESSARY FROM CHILDREN AND PETS BY WHATEVER MEANS NECESSARY MOVING DEVICES ALWAYS PRESENT PEOPLE PETS AND PROPERTY WITH CERTAIN RISKS AND HAVE POTENTIAL FOR HARM THE FOLLOWING LIST OF PRECAUTIONS HAS BEEN PREPARED FOR YOUR REVIEW THIS LIST IS NOT ALL INCLUSIVE NOR IS IT REPR...

Page 29: ...WHICH COULD BE ENTRAPPED NO MATTER HOW UNLIKELY IT MAY APPEAR AT FIRST GLANCE 8 ENSURE ALL SAFETY DEVICES ARE TESTED REGULARLY 9 DO NOT TIGHTEN CLUTCHES OR INCREASE PRESSURES TO COMPENSATE FOR A POOR GATE SYSTEM DESIGN AND OR THE GATE LEAF 10 INSTALL WARNING SIGNS ON BOTH SIDES OF THE GATE LEAF 11 HAVE PROPER LIGHTING INSTALLED FOR NIGHT TIME USE 12 NEVER BECOME COMPLACENT WITH THE OPERATION OF A ...

Page 30: ...ORY EQUIPMENT ARE INTENDED TO BE PART OF A TOTAL OPERATING SYSTEM WE HIGHLY ENDORSE AND RECOMMEND THE USE OF SAFETY ACCESSORIES AND VISUAL WARNING INDICATORS IN THE FORM OF LIGHTS SOUNDERS AND PLACARDS PROPERLY PLACED IT IS THE RESPONSIBILITY OF THE PURCHASER DESIGNER AND INSTALLER THAT THE TOTAL SYSTEM IS SAFE FOR THE PARTICULAR APPLICATION WE ARE PLEASED YOU HAVE SELECTED BYAN SYSTEMS ROQUET OPE...

Reviews: