background image

Manufactured By

Byan Systems, Inc. 

413 Linden 

Lusk, WY 82225 

(307)334-2865 
(800)223-2926

 

 

 

Wiring Instructions 

Byan Systems G2M Control Board

 

ONLY

 

 

Commercial Power:

   

Connect incoming commercial power to TB1 using method described on page one of this 
manual. 

 

Gate Control System: 

 

Connect outgoing power to TB2 in the battery back-up using included wiring 

1.   115VAC Hot (Black) 
2.   115VAC Neutral (White) 
3.

 

Earth Ground (Green) 

Connect outgoing power to the high voltage terminal block on the G2M control board 

not

 

installed in a Byan Systems prewire. 

1.

 

115VAC Neutral (White) 

2.

 

115VAC Hot (Black) 

Or the power-in terminal block (TB1) on the Byan Systems prewire. 

2.   115VAC Hot (Black) 
3.

 

115VAC Neutral (White) 

4.

 

Earth Ground (Green) 

 

Gate Control Functions: 

Connect supplied function control wiring harness to TB3 in a battery back-up to accessory 
terminals on the G2M control board not installed in a Byan Systems prewire. 

 

SBBI TB3 

 

 

                    

G2M Accessory Terminals 

               1 Empty  

 

 

 

 

 

Not Used 

 2 Black   

 

 

 

 

 

18 master board 

               3 White  

 

 

 

 

 

16 master board 

               4 Green/ jumper from 3 

 

 

 

 

16 master board 

               5 Brown 

 

 

 

 

 

19 master board 

               6 Red   

 

 

 

 

 

19 slave board 

               7 Jumper from 8   

 

 

 

 

16 slave board 

               8 Green  

 

 

 

 

 

16 slave board 

               9 Blue   

 

 

 

 

 

18 slave board 

             10 Empty  

 

 

 

 

 

Not used 

 

Control Function wiring may also be connected to corresponding terminal blocks on the Byan 
Systems prewire: 
 
     

SBBI 

12x10  G2M 

 

20x16  G2M 

 

24x20  G2M 

       TB3                     TB3   

                     TB5  

                TB5 & TB7 

   3,4 & 7,8              Green 23 

                  Green 23 

 

    Green 23 

      2 &  9 

   Purple 24 

 

   Purple 24 

 

    Purple 24 

      5 &  6 

  Orange 25 

 

  Orange 25 

 

   Orange 25 

 

Summary of Contents for SBBI-2

Page 1: ... the top of page 2 2 5 Foot Lead In Cables for Battery to Inverter Connection 100 Amp Fuse for Installation between Positive Battery Terminal and Inverter Fuse Holder Customer supplied Items Battery see page 3 for Selection Guidelines Battery Enclosure Weather Resistant Enclosure Connectors Commercial Power Input Wiring Installation and Wiring Instructions Inverter Installation 1 Unpack inverter f...

Page 2: ...gle phase commercial power to TB1 1 115VAC Hot Black 2 115VAC Neutral White 3 Earth Ground Green Device Control Functions Connect supplied function control wiring harness 18 6 cord to TB3 1 Remote control device 2 Motor 1 open contact 3 Motor 1 open common 4 Motor 1 cycle common 5 Motor 1 cycle contact 6 Motor 2 cycle contact 7 Motor 2 cycle common 8 Motor 2 open common 9 Motor 2 open contact 10 N...

Page 3: ... are shipped in a separate package Fuse is already installed on positive battery cable CAUTION Connect battery only after commercial power is connected and turned on to the device Connecting battery before commercial power is turned on could result in device moving and possibly injuring persons or causing damage to property Battery Selection Guidelines SBBI recommends 12VDC Maintenance Free sealed...

Page 4: ...inverter is started first gate s is commanded to open after about 60 seconds second gate s is commanded to open after 60 seconds inverter is stopped and system waits for power restoration After power restoration power is verified for about 10 seconds a cycle command is issued causing gates to operate to the closed position DIP SWITCH SELECTION Position 1 Down Selects single gate system operation S...

Page 5: ...e Byan Systems prewire 2 115VAC Hot Black 3 115VAC Neutral White 4 Earth Ground Green Gate Control Functions Connect supplied function control wiring harness to TB3 in a battery back up to accessory terminals on the G2M control board not installed in a Byan Systems prewire SBBI TB3 G2M Accessory Terminals 1 Empty Not Used 2 Black 18 master board 3 White 16 master board 4 Green jumper from 3 16 mas...