Terminal Strips:
There are two sets of terminals on the G2M+ control board. The first terminal strip is the Power and Motor
Run Terminal Block, located on the left side of the board below the transformer. This is where the incoming
commercial power and the outgoing power to the operators are connected. This terminal strip is made up of
three terminal blocks: 1) In-coming Power; 2) Motor One; and 3) Motor Two.
Power and Motor Run Terminals
Terminal Number
Terminal Name / Description
Wire Colors
1
Commercial Power Input Neutral
115V White / 220V Black
2
Commercial Power Input Hot
115V Black / 220V Red
3
Motor One Close Directional
Black
4
Motor One Open Directional
Red
5
Motor One Common
White
6
Motor Two Close Directional
Black
7
Motor Two Open Directional
Red
8
Motor Two Common
White
Commercial Power Hook-Up*:
1.
Hook up commercial power to Terminals 1 and 2 of the Power and Motor Run Terminal Strip.
2.
Connect leads from the Motor No. 1 operator to Terminals 3, 4, and 5 of the Power and Motor Run
Terminal Strip.
3.
Connect leads from the Motor No. 2 operator to Terminals 6, 7 and 8 of the Power and Motor Run
Terminal Strip.
4.
Connect Motor Run Capacitors across each set of directional motor leads (between Terminals 3 and 4,
and Terminals 6 and 7).
115V White / 220V Black
115V Black / 220V Red
Capacitor
Capacitor
Black
Black
Red
Red
White
White
Motor 1
Motor 2
1
2
3
4
5
6
7
8