-24-
MODEL 600 SERIES OPERATOR | Rev. 2019.7.1
Accessory Hook-Ups*:
There are many accessories available that are compatible with the G2M+ that will give the end user different
options for safety, security, and system operations. Since it would be impossible to outline all possible
combinations, we will simply outline a few of the most common. Keep in mind; these instructions are specific
to the brand and model most commonly used by Byan Systems. Your accessories may differ from the ones
listed below.
ALWAYS consult the Installation Instructions included with an accessory before connecting it
to any operating system.
Per the current UL 325 requirements, all new automated gate systems (post 2016) require a minimum of two
monitored entrapment prevention devices, separately connected. Monitoring
MUST
occur in both open and
close functions. You must also have either an audible or visual alarm device in operation.
The Byan Systems G2M+ Control Board is capable of handling a maximum of 8 accessories (wired together in
series) and one accessory wired in parallel.
Linear GRD_1 Radio Receiver:
1. Separate the four wires coming out of the bottom of the Receiver (1 Red, 1 Black, and 2 Gray).
2. Connect the black wire to Terminal 3 of the Accessory Terminal Strip.
3. Connect the red wire to Terminal 4 of the Accessory Terminal Strip.
4. Connect one of the gray wires to Terminal 16 of the Accessory Terminal Strip.
5. Connect the other gray wire to Terminal 18 of the Accessory Terminal Strip for open only or Terminal 19 for use as a
reversing device.
6. If an external antenna is required, locate the Bulk Head Connector supplied with the Receiver.
7.
Drill one 3/8” hole in the enclosure where you would like to mount the antenna.
8. Install the Bulk Head Connector in the hole using the hardware included with the Receiver. Be sure to use thread
locking compound in the threads when installing the connector.
9. Connect the supplied coax between the Receiver and the Bulk Head Connector and attach the antenna to the outside
of the connector.
Mag-Lock Relay Using IDEC SH2B-05 Base w/RH2B-UDC12V Relay:
1. Connect Terminal 13 on the Relay Base to Terminal 5 of the Accessory Terminal Strip on the board.
2. Connect Terminal 14 on the Relay Base to Terminal 6 of the Accessory Terminal Strip on the board.
3. Connect Neutral or Ground from the Mag-Lock Transformer directly to the Mag-Lock.
4. Connect Hot from the Mag-Lock Transformer to Terminal 9 of the Relay Base.
5. Connect Terminal 1 on the Relay Base to the Mag-Lock.
Loop Detector Using IDEC SR3P-06 Base w/EDI LMA1500-120 Loop Detector:
1. Connect Terminals 7 and 8 to the in-ground loop leads.
2. Connect 120-Volt AC Neutral to Terminal 2 of the Detector Base.
3. Connect 120-Volt AC Hot to Terminal 1 of the Detector Base.
4. Connect desired signal wires from the Detector Base to the Accessory Terminal Strip of the G2M+.
Shadow Using IDEC SH2B-05 Relay Base and RH2B-UAC110-120 Relay:
1. Connect Terminal 9 of the Relay Base to Terminal 5 of the Detector Base.
2. Connect Terminal 5 of the Detector Base to Terminal 9 of the Accessory Terminal Strip.
3. Connect Terminal 5 of the Relay Base to Terminal 10 of the Detector Base.
4. Connect Terminal 10 of the Detector Base to Terminal 10 of the Accessory Terminal Strip.
Safety:
1. Connect Terminal 5 of the Detector Base to Terminal 9 of the Accessory Terminal Strip.
2. Connect Terminal 10 of the Detector Base to Terminal 10 of the Accessory Terminal Strip.
Free Exit:
1. Connect Terminal 5 of the Detector Base to Terminal 16 of the Accessory Terminal Strip.
2. Connect Terminal 6 of the Detector Base to Terminal 18 of the Accessory Terminal Strip.
The Byan Systems G2M+ Control Board is UL 325 compliant and monitors devices in both directions (open and close). This
means that if the gate comes into contact with an object, it will stop and reverse briefly. If the object is hit a second time,
or if a monitored safety device fails, the board will lock out and must then be manually reset before the system will operate
again. (This includes a broken photocell beam.)