-29-
MODEL 600 SERIES OPERATOR | Rev. 2019.7.1
24 x 20 PREWIRE TERMINAL STRIP GUIDE
TB1 COMMERCIAL POWER
TB2 OPERATOR MOTOR TERMINALS
1
220-VOLT AC HOT
(RED)
5
UNINTERRUPTIBLE 115-VOLT AC
(BLACK)
2
115-VOLT AC HOT
(BLACK)
6
UNINTERRUPTIBLE 115-VOLT AC
(WHITE)
3
115-VOLT AC NEUTRAL
(WHITE)
7
GROUND
(GREEN)
4
GROUND
(GREEN)
TB4
EXIT
OPERATOR MOTOR TERMINALS
TB3 OPERATOR MOTOR TERMINALS
10 GROUND
(GREEN)
10 GROUND
(GREEN)
11 MOTOR 1 DIRECTIONAL
(BLACK)
11 MOTOR 1 DIRECTIONAL
(BLACK)
12 MOTOR 1 DIRECTIONAL
(RED)
12 MOTOR 1 DIRECTIONAL
(RED)
13 MOTOR 1 COMMON
(WHITE)
13 MOTOR 1 COMMON
(WHITE)
14 GROUND
(GREEN)
14 GROUND
(GREEN)
15 MOTOR 2 DIRECTIONAL
(BLACK)
15 MOTOR 2 DIRECTIONAL
(BLACK)
16 MOTOR 2 DIRECTIONAL
(RED)
16 MOTOR 2 DIRECTIONAL
(RED)
17 MOTOR 2 COMMON
(WHITE)
17 MOTOR 2 COMMON
(WHITE)
TB7
EXIT
ACCESSORY TERMINALS
TB5 ENTRY ACCESSORY TERMINALS
24+
MONITORED SAFETY
(RED)
24+
MONITORED SAFETY
(RED)
18
24-VOLT AC COMMON
(BLACK)
18
24-VOLT AC COMMON
(BLACK)
19
24-VOLT AC POSITIVE
(RED)
19
24-VOLT AC POSITIVE
(RED)
20
PEOPLE SAFE (NORMALLY CONNECTED)
(WHITE)
20
PEOPLE SAFE (NORMALLY CLOSED)
(WHITE)
COMMON SAFETY
COMMON SAFETY
22
CAR SAFE
(BLUE)
22
CAR SAFE
(BLUE)
23
COMMON OPEN / REVERSING
(GREEN)
23
COMMON OPEN / REVERSING
(GREEN)
24
COMMAND OPEN (NORMALLY OPEN)
(PURPLE)
24
COMMAND OPEN (NORMALLY OPEN)
(PURPLE)
25
COMMAND REVERSING (NORMALLY OPEN)
(ORANGE)
25
COMMAND REVERSING (NORMALLY OPEN)
(ORANGE)
TB8
EXIT
LOOP TERMINALS
TB6 ENTRY LOOP TERMINALS
26 FREE EXIT LOOP
(GRAY)
28 SAFETY LOOP
(GRAY)
27 FREE EXIT LOOP
(BROWN)
29 SAFETY LOOP
(BROWN)
28 SAFETY LOOP
(GRAY)
30 SHADOW LOOP
(GRAY)
29 SAFETY LOOP
(BROWN)
31 SHADOW LOOP
(BROWN)
30 SHADOW LOOP
(GRAY)
32 MAG-LOCK
(BROWN)
31 SHADOW LOOP
(BROWN)
33 MAG-LOCK
(BROWN)
32 MAG-LOCK
(BROWN)
33 MAG-LOCK
(BROWN)
TB9 ENTRY INTERRUPTED VOLTAGE TERMINALS
8
INTERRUPTED HIGH VOLTAGE 115-VOLT AC
(BLACK)
TB10
EXIT
INTERRUPTED VOLTAGE TERMINALS
9
INTERRUPTED HIGH VOLTAGE 115-VOLT AC
(WHITE)
8
INTERRUPTED HIGH VOLTAGE 115-VOLT AC
(BLACK)
9
INTERRUPTED HIGH VOLTAGE 115-VOLT AC
(WHITE)
NOTE: WHEN LEAF DELAY IS ENGAGED, MOTOR 1 WILL OPEN FIRST AND MOTOR 2 WILL CLOSE FIRST.