B-Box Professional installation guidance
7 Battery address set up
7.1 “ADDR” switch introduction
Function: For communication between battery and BMU. BMU will communicate with external equipment by using CAN communication.
Each DIP switch definition:
There are 6 bit switches, keep the switch on down side means”0”, turn up the switch to “ON” means “1”.
Address: 000000 Address:100000
For example: when two battery in using, “ADDR” setting:
No.1 battery address: 100000 No.2 battery address: 010000
For address setting, please refer to the configuration list in next page.
Note: Make sure of the highest address of B-Plus2.5 connect to BMU.
18
/
38