TRANSPORTATION AND STORAGE
OPERATOR MANUAL
34
EPS14P
35
OM-EPS14P2019001-EN
STORE AND RESTART
Procedures of Store
Clean and remove the dust on the forklift components and conduct the following procedures
:
(1) Check forklift for any leakage and abnormal components. If yes, repair the forklift first.
(2) Fully lift and lower the forks several times.
。
(3) Lower the forks.
(4) Spray a layer of lubricant over the parts left unpainted.
(5) Check the hydraulic oil level and add if necessary.
(6) Lubricate all the components.
。
(7) Take off the key and make sure that forklift is disconnected from the battery power and
press down the emergency disconnect switch. Battery status of charge should be around
50% to avoid over-discharge or full charge for long-term storage.
(8) Use and operate the forklift for a while every month.
Procedures to Restart
Clean and remove the dust on the forklift components and conduct the following procedures
:
(1) Lubricate all the components.
。
(2) Fully lift and lower the forks and tilt masts several times.
(3) Check the status of charge of the traction battery.
(4) Check the hydraulic oil. Replace it if necessary.
Caution
The operator should repeatedly check the performance of the forklift brake when operating it
for the first time after the forklift has been restored to service.
MAINTENANCE
This chapter explains how to maintain the forklift.