Protective Gear

Personal Protective Equipment (PPE) must comply with the American National 
Standards Institute’s ANSI Z87.1-1989 standard if purchased after July 5, 1994, 
or ANSI Z87.1-1968 or with the standard of the country in use.

Eye and face PPE shall be distinctly marked to facilitate identification of the 

manufacturer. (1910.133[a][4]).

The following minimum requirements must be met by all protective devices. 

Protectors shall:

-

Provide adequate protection against the particular hazards for which they 

are designed

-

Be of safe design and construction for the work to be performed

-

Be reasonably comfortable when worn under the designated conditions

-

Fit snugly and not unduly interfere with the movements

of the wearer

-

Be durable

-

Be capable of being disinfected

-

Be easily cleanable

-

Be distinctly marked to facilitate identification only of the manufacturer

R

ECOMMEND USE OF FULLY ENCLOSED EYEWEAR  

PROTECTIONS, SUCH AS GOGGLES, WHEN USING THIS DEVICE.

 

ALWAYS USE APPROPRIATE PPE

.

IMPORTANT SAFETY PRECAUTIONS

When using an electrical appliance, it is important to understand that some circuits 
are electrically live, even when the power switch is in the off position. Basic safety 
precautions should always be followed to reduce the risk of burns, fire, electrical 
shock, injury and/or death. 

Power Connection

Our power plug must be used with a three-pronged, grounded outlet, rated for no 
less than 15A service. Always verify before product use. This appliance is for use 
on a nominal 120V/60Hz circuit with a verified ground plug. Check with a qualified 
electrician to ensure you have the correct electrical service and grounding.

COVER OF 

GROUNDING  OUTLET BO

GROUNDED

X*

 

PIN

*120-volt grounded connectors shown. 220/240-volt grounded connectors will differ in shape.

Grounding Instructions

This appliance must be grounded. In the event of malfunction 
or breakdown, grounding provides a path of least resistance for an electric current 
to reduce the risk of electric shock. This appliance is equipped with a cord having 
an equipment-grounding conductor and a grounding plug. The plug must be 
plugged into an appropriate outlet that is properly installed and grounded in 
accordance with all local codes and ordinances. Never use an adapter with this 
product.

DANGER:

 Improper connection of the equipment-grounding conductor can result in 

a risk of electric shock. The conductor with insulation having an outer surface that is 
green, with or without yellow stripes, is the equipment-grounding conductor. If repair or 
replacement of the cord or plug is necessary, do not connect the equipment-grounding 
conductor to a live terminal. Check with a qualified electrician or serviceman if the 
grounding instructions are not completely understood or if in doubt as to whether the 
appliance is properly grounded. Do not modify the plug provided with the appliance — 
if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Never 
use an adapter with this product.

Extension Cord

ByoPlanet provides a 25-foot (7.6m) extension cord with each Electrostatic Spray 
System and strongly recommends that you use  this approved extension cord. 
Make sure your extension cord is in  good condition. Inspect cords periodically and 
replace if damaged.  If an alternate extension cord is used, be aware that an 
undersized extension cord will cause a drop of in-line voltage, which 
could result in a loss of power, damage to the product and/or overheating. Always 
use a sufficiently rated extension cord.

IMPORTANT:

 ByoPlanet recommends using a 12/3 gauge extension cord, no 

longer than 100 feet (30.5m). Additionally, ByoPlanet also recommends the use of 
a GFCI (ground fault circuit interrupter) power outlet or extension cord. When 
equipped on the extension cord, always position the GFCI toward the power outlet.

 EN

  | 

5

Summary of Contents for CS-2015 Series

Page 1: ...utdoor Commercial Use Operator s Manual 2 13 For service and support contact Service Tech Team www servicetechteam com EN ByoPlanet Compact Cart Electrostatic Spray Systems Electrostatic Sprayer MS 715 CS 2015 Series Electrostatic Sprayer MS 740 CS 2040 Series ...

Page 2: ...xtension Cord Shock Electrical Hazard General Safety Chemicals ByoPlanet MS 715 MS 740 Compact Series Base Unit ByoPlanet ES 150 Electrostatic Sprayer Nozzle ByoPlanet CS 2015 CS 2040 Cart Series OPERATING INSTRUCTIONS Preparing the Spray Area Unit Preparation Setup Sprayer Operation During Use Changing ByoPlanet Approved Products After Use and Storage MAINTENANCE Sprayer Body Peristaltic Pump Noz...

Page 3: ...ined personnel WARNINGS PRESSURIZED EQUIPMENT HAZARD Fluid from equipment that leaks or ruptures from a component can splash in the eyes or on skin causing serious injury In order to help prevent a leak or rupture Check hoses tubes and couplings daily Replace worn or damaged parts immediately WARNINGS PLASTIC PARTS CLEANING SOLVENT HAZARD Many solvents can degrade plastic parts and cause them to f...

Page 4: ...Systems can only be used with products that have been approved by ByoPlanet Never spray any liquid product that is not a ByoPlanet approved product The ByoPlanet Electrostatic Spray Systems warranty is voided if the ByoPlanet Electrostatic Spray Systems are used with products that are not approved by ByoPlanet Be aware that many chemical liquids can be harmful if they are not used properly Read an...

Page 5: ... must be grounded In the event of malfunction or breakdown grounding provides a path of least resistance for an electric current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ord...

Page 6: ...m cord 12 13 A sprayer should never be left unattended when plugged in A resettable breaker is provided on the rear of the unit It will trip if the unit experiences an electrical short 14 Always turn off sprayer after each application and before unplugging 15 16 Always unplug unit from outlet when not in use or when leaving it unattended Never unplug by pulling the cord or with wet hands Always un...

Page 7: ...ects any dripping from the sprayer 7 Adjustable Handle Handle position is raised lowered and rotated by the two button snaps 8 Peristaltic Pump Provides liquid up to sprayer 9 Circuit Breaker User resettable circuit breaker and will only trip if a short occurs in the base unit 10 Main Power Switch Powers system to a ready state 11 1 Gallon Chemical Containers Chemical containers not included with ...

Page 8: ...dle grips 3 Reel Mounting Plate Reel is mounted to this plate 4 Sprayer Holster Holds the sprayer 5 Removable Drip Cup Collects any dripping from the sprayer 6 Extension Cord Hook Holds the extension cord when not in use ByoPlanet CS 2015 CS 2040 Cart Series Base Unit 1 Base Unit Contains pump controls etc 2 Cart Provides unit mobility 3 Reel Retracts and stores hose CS 2015 Base Unit Comprised of...

Page 9: ...System base unit 8 Store in a safe dry place 1 Clean gross filth by using standard manual cleaning protocols 2 Close the room to the general public for cleaning Place signs or warning indicators on doors that indicate no one should enter the room 3 Power off any sensitive electrical devices but do not unplug them Unit Preparation Setup 1 Choose the appropriate Byoplanet approved product for cleani...

Page 10: ...h a pair of pliers Otherwise service the spring loaded contact by applying a generous amount of dielectric grease available at any local automotive hardware store 4 Be sure to also thoroughly clean all interior surfaces of the nozzle cover including the main orifice Never use a wire brush file or sandpaper to clean any surface or orifice Important The nozzle cover should be hand tightened Never us...

Page 11: ...V Model Volts 240V Running AMPS 3 0 Startup AMPS 7 0 Frequency 50 Hz Standard Hose Length 7 ft 2 13 m Dimensions 29 25 in 0 74m H x 10 00 in 0 25m W x 16 00 in 0 40m L Air Line Pressure 35 psi 2 4 Bar Weight Empty 43 lbs 20 kg Weight Full 59 lbs 27 kg Shipping Weight 52 lbs 24 kg Flow Rate 4 3 oz min 130ml min Volts 240V Running AMPS 3 0 Startup AMPS 7 0 Frequency 50 Hz Standard Hose Length 30 ft ...

Page 12: ...Unit stalls at initial trigger This may be a sign of a cold start Warm unit up by pressing the trigger and letting unit run for up to two minutes Trigger off then on Unit should run normally TROUBLESHOOTING NOTE Do NOT use a chemical in the unit that is not a ByoPlanet approved product If you encounter the issues listed below use the suggested troubleshooting methods If you encounter an issue that...

Page 13: ... by ByoPlanet duty taxes charges for normal service or adjustments loss of income expenses due to loss damage detention or delay in the delivery of equipment or parts resulting from acts beyond the control of ByoPlanet THIS WARRANTY SHALL NOT APPLY TO 1 Defects failures damages or performance limitations caused in whole or in part by a b Power failures surges accidents actions of third parties wea...

Page 14: ... Road Sunrise FL 33326 1 855 211 1518 www byoplanet com ByoPlanet International LLC 1002 Winterville Road Athens GA 30605 1 855 211 1518 www byoplanet com Electrostatic Sprayer MS 715 CS 2015 Series Electrostatic Sprayer MS 740 CS 2040 Series ...

Reviews: