Protective Gear
Personal Protective Equipment (PPE) must comply with the American National
Standards Institute’s ANSI Z87.1-1989 standard if purchased after July 5, 1994,
or ANSI Z87.1-1968 or with the standard of the country in use.
•
Eye and face PPE shall be distinctly marked to facilitate identification of the
manufacturer. (1910.133[a][4]).
•
The following minimum requirements must be met by all protective devices.
Protectors shall:
-
Provide adequate protection against the particular hazards for which they
are designed
-
Be of safe design and construction for the work to be performed
-
Be reasonably comfortable when worn under the designated conditions
-
Fit snugly and not unduly interfere with the movements
of the wearer
-
Be durable
-
Be capable of being disinfected
-
Be easily cleanable
-
Be distinctly marked to facilitate identification only of the manufacturer
R
ECOMMEND USE OF FULLY ENCLOSED EYEWEAR
PROTECTIONS, SUCH AS GOGGLES, WHEN USING THIS DEVICE.
ALWAYS USE APPROPRIATE PPE
.
IMPORTANT SAFETY PRECAUTIONS
When using an electrical appliance, it is important to understand that some circuits
are electrically live, even when the power switch is in the off position. Basic safety
precautions should always be followed to reduce the risk of burns, fire, electrical
shock, injury and/or death.
Power Connection
Our power plug must be used with a three-pronged, grounded outlet, rated for no
less than 15A service. Always verify before product use. This appliance is for use
on a nominal 120V/60Hz circuit with a verified ground plug. Check with a qualified
electrician to ensure you have the correct electrical service and grounding.
COVER OF
GROUNDING OUTLET BO
GROUNDED
X*
PIN
*120-volt grounded connectors shown. 220/240-volt grounded connectors will differ in shape.
Grounding Instructions
This appliance must be grounded. In the event of malfunction
or breakdown, grounding provides a path of least resistance for an electric current
to reduce the risk of electric shock. This appliance is equipped with a cord having
an equipment-grounding conductor and a grounding plug. The plug must be
plugged into an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances. Never use an adapter with this
product.
DANGER:
Improper connection of the equipment-grounding conductor can result in
a risk of electric shock. The conductor with insulation having an outer surface that is
green, with or without yellow stripes, is the equipment-grounding conductor. If repair or
replacement of the cord or plug is necessary, do not connect the equipment-grounding
conductor to a live terminal. Check with a qualified electrician or serviceman if the
grounding instructions are not completely understood or if in doubt as to whether the
appliance is properly grounded. Do not modify the plug provided with the appliance —
if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Never
use an adapter with this product.
Extension Cord
ByoPlanet provides a 25-foot (7.6m) extension cord with each Electrostatic Spray
System and strongly recommends that you use this approved extension cord.
Make sure your extension cord is in good condition. Inspect cords periodically and
replace if damaged. If an alternate extension cord is used, be aware that an
undersized extension cord will cause a drop of in-line voltage, which
could result in a loss of power, damage to the product and/or overheating. Always
use a sufficiently rated extension cord.
IMPORTANT:
ByoPlanet recommends using a 12/3 gauge extension cord, no
longer than 100 feet (30.5m). Additionally, ByoPlanet also recommends the use of
a GFCI (ground fault circuit interrupter) power outlet or extension cord. When
equipped on the extension cord, always position the GFCI toward the power outlet.
EN
|
5