Preparing the Spray Area
1.
Clean gross filth by using standard manual cleaning
protocols.
2. Close the room to the general public for cleaning. Place
signs or warning indicators on doors that indicate no one
should enter the room.
3. Power off any sensitive electrical devices. Devices do not
need to be unplugged.
Unit Operation/Setup
1.
Choose the appropriate ByoPlanet
®
-approved product
for cleaning, sanitizing or disinfecting.
2. Put on appropriate PPE. See section on PPE on page 5.
3. Mount desired ByoPlanet
®
-approved product on
ByoPlanet
®
MS-700™ Electrostatic Sprayer base. Ensure
that the bottles are positioned with the opening facing
up and towards the dispensing tubes.
4. Unscrew the lid on the ByoPlanet
®
-approved product of
your choice, remove seal (if present), and connect the
ByoPlanet
®
MS-700™ Electrostatic Sprayer dispensing
cap to the bottle. Be sure the cap is screwed all the way
down; do not overtighten.
5. Unwrap electrical cord completely and plug ByoPlanet
®
MS-700™ Electrostatic Sprayer into a grounded,
three-pronged outlet. See EXTENSION CORD section
for extension cord specifications.
NOTE: For outside or wet environment application, use
a GFCI (ground fault circuit interrupter) inline adapter
or outlet to help avoid risk of electrical shock. The GFCI
should be placed as close to the outlet as possible.
6. Locate the On/Off switch on the base unit. Push the
ByoPlanet
®
MS-700™ sprayer to the “ON” position.
A light will illuminate on the sprayer instrument panel.
7.
Remove the sprayer from the unit.
8. The system is now ready for use.
9. Priming the ByoPlanet
®
MS-700™ Electrostatic Sprayer:
Depress into an inconspicuous corner, container or drain.
Spray the ByoPlanet
®
MS-700™ Electrostatic Sprayer for
up to 20 seconds to generate a steady flow of solution.
10. When spraying, a second indicator light will illuminate on
the sprayer instrument panel when the sprayer button is
depressed.
NOTE: Sprayer will automatically stay on until sprayer
button is depressed an additional time.
NOTE: Unit will not operate properly below 55°F
(12.5°C). If unit has been stored where temperatures are
below 55°F (12.5°C) move the unit to a warm environ-
ment and allow the unit to acclimate before operation.
Sprayer Operation
11. Position ByoPlanet
®
MS-700™ Electrostatic Sprayer in a
rear corner of the area.
12. Direct the spray wand at the desired surface.
13. Begin to spray. Press the sprayer button once to initiate
spraying. Press once to stop flow of the sprayer.
14. Follow a continuous path around the area, working
from hig to low areas, moving the sprayer in a sweeping
motion until surfaces are thoroughly wet. Optimal spray
distance away from surface is 2–4 feet (0.6–1.2 meters).
15. After spraying, keep the area closed to the public until
applicable bystander re-entry times are reached (see
the product SDS for information on bystander re-entry
times). If no re-entry time is indicated, keep the area
closed until productcontact times are reached or
surfaces are visibly dry.
16. Remove the closed sign from the door.
Changing ByoPlanet
®
-Approved Products
1.
Stop spraying the ByoPlanet
®
MS-700™ Electrostatic
Sprayer.
2. Disconnect the bottle connection from the ByoPlanet
®
-approved product that is to be changed and remove
from the sprayer. Cap the removed product if it is
being stored.
3. Purging the ByoPlanet
®
MS-700™ Electrostatic Sprayer:
Depress into an inconspicuous corner, container or drain.
Spray the ByoPlanet
®
MS-700™ Electrostatic Sprayer for
up to 20 seconds to purge the system.
4. Choose the appropriate ByoPlanet
®
-approved product
for cleaning, sanitizing or disinfecting.
5. Mount desired ByoPlanet
®
-approved product on
ByoPlanet
®
MS-700™ Electrostatic Sprayer base. Ensure
that the bottles are positioned with the opening facing
up and towards the dispensing tubes.
6. Unscrew the lid on the ByoPlanet
®
-approved product of
your choice, remove seal (if present), and connect the
ByoPlanet
®
MS-700™ Electrostatic Sprayer dispensing
cap to the bottle. Be sure the cap is screwed all the way
down; do not overtighten.
7.
Priming the ByoPlanet
®
MS-700™ Electrostatic Sprayer:
Depress into an inconspicuous corner, container or drain
Spray the ByoPlanet
®
MS-700™ Electrostatic Sprayer for
up to 20 seconds to generate a steady flow of solution.
After Use and Storage
1.
Stop spraying the ByoPlanet
®
MS-700™ Electrostatic
Sprayer.
2.
Disconnect the bottle connection from the ByoPlanet
®
-approved product that is to be changed and remove
from the sprayer. Cap the removed product if it is
being stored.
3. Emptying drip cup holder (if necessary): Unscrew drip
cup, making sure to hold it level to prevent spillage.
Remove and empty the drip cup. Reinstall the empty drip
cup by rotating it in the opposite direction until it is snug.
4. Purging the ByoPlanet
®
MS-700™ Electrostatic Sprayer:
Depress into an inconspicuous corner, container or drain.
Spray the ByoPlanet
®
MS-700™ Electrostatic Sprayer
until no liquid comes out of the nozzle.
5. Turn off the unit. Indicator lights on the sprayer
instrument panel should no longer be illuminated
and power button should be in the OFF position.
6. Unplug the ByoPlanet
®
MS-700™ Electrostatic Sprayer
from wall.
7.
Wrap cord on cord holder on the MS-700™ base unit.
8. Store in a safe, dry place.
OPERATING INSTRUCTIONS
8 | ENGLISH
BYOPLANET.COM