In order for the ByoPlanet
®
MS-700™ Electrostatic Sprayer
to remain functional, the equipment should be cleaned on a
regular basis. In addition to general cleaning of the unit, one
user-serviceable area — the peristaltic pump — may need to
be serviced.
NOTE: As the sprayer becomes dirty from typical use, a
70% isopropyl alcohol cleaner that is manually applied is
recommended on outside surfaces.
The sprayer body has no serviceable parts inside. DO NOT
OPEN THE SPRAYER SHELL, AS DOING SO WILL VOID THE
WARRANTY ON THE SPRAYER. If you need to have your
sprayer serviced, contact Service Tech Team at
www.servicetechteam.com.
Exterior Frame
To clean the exterior of the ByoPlanet
®
MS-700™
Electrostatic Sprayer
1.
Purge all chemistry from the device.
2. When not in use, ensure the device is powered off and
unplug the power cord from the wall outlet and device.
3. Wipe exterior surfaces of the device, including hose and
nozzle, with a slightly damp cloth or towel to remove
visible soil. Be sure that the cloth is well wrung out, and
excess moistur has been removed.
4. For additional soil removal, wipe the exterior surfaces
with a microfiber cloth that has been soaked in warm,
soapy water Be sure that the cloth is well wrung out, and
excess moisture has been removed.
5. Let device dry thoroughly before operation is resumed.
Peristaltic Pump
1.
Disconnect the clear tubing inlet and outlet by twisting
the Tube Nuts counterclockwise until both tubes have
separated.
2. Rotate the Cover counterclockwise and pull the pump
assembly free from the unit.
3. Install the new Pump Assembly in the reverse order that
it was disassembled.
MAINTENANCE
ENGLISH | 9
BYOPLANET.COM