ITEM NO.

PART NO.

DESCRIPTION

ITEM NO.

PART NO.

DESCRIPTION

1

See Air Cap Chart  

Air Cap**

19

60-2101

Trigger

2

See Air Cap Chart

Fluid Tip**

20

60-1520

Air Valve Assembly

3

33-1202

Fluid Nozzle Body

21

60-302

Air Valve Poppet

4

98-8026

O-Ring*

22

60-125

Seal*

5

60-J31H

Nozzle Body Carrier

23

61-1003

Air Valve Spring*

6

60-123

Seal*

24

60-119

Seal*

7

60-34H

Air Cap Adapter

25

60-201

Rear Bushing

8

60-131

O-Ring*

26

60-204

Needle Return Spring*

9

60-124

Seal*

27

60-205

Spring Seat*

10

60-130

Seal*

28

60-202

Fluid Control Knob*

11

60-118

Locknut

29

60-1510

Inlet Air Control (Optional)

12

60-127

Fluid Inlet

30

60-122

Plug

13

60-1119-CPR-H2O

CPR-Gravity Gun Body

31

60-104

Air Inlet Fitting

14

98-0109

Allen Plug

51-401 Standard 700 mL Gravity Feed Cup (Aluminum)

15

See Air Cap Chart

Fan Control Assembly**

51-400 Optional 700 mL Gravity Feed Cup (Plastic)

16

See Air Cap Chart

Fluid Needle**

51-403 Optional 1000 mL Gravity Feed Cup (Aluminum)

17

60-1400

Needle Seal*

51-418

Gravity Cup Lid (401 & 403)

18

60-1033

Trigger Pivot Set

51-413

Gravity Cup Lid (400)

**See air cap selection chart on page 1

*Indicates part included in repair kit # 10-105

32

33

23-1301-G

HVLP AIR CAP TEST GAGES

FOR

H2O-CPR-G

Summary of Contents for H2O-CPR-G

Page 1: ...G Note Air cap test gages are available to confirm HVLP compliance H2O CPR G PPS Gun inlet pressures may vary as required by application 11 13 5 H2O CPR G 60 1504 S 23 2101 CPR Pressure Reduced 23 1301 HVLP 0 8 1 7 0 8 2 2 29 29 H2O CPR G GRAVITY FEED SPRAY GUN PRODUCT INFORMATION Coating Atomization Technologies 337 South Arthur Avenue Louisville CO 80027 Phone 888 820 4498 Fax 303 438 5708 www s...

Page 2: ...ssembly instructions Have repair kit 10 105 available before gun disassembly Gun head disassembly To remove the nozzle carrier 5 and air cap adapter 7 1 Remove the air cap 1 fluid nozzle tip 2 fluid nozzle body 3 and needle 16 2 Remove the needle seal cartridge 17 3 Loosen the locknut 11 and remove fluid inlet 12 using a 11 16 open end wrench 4 The nozzle carrier 5 and air cap adapter 7 will now s...

Page 3: ...l 28 60 202 Fluid Control Knob 11 60 118 Locknut 29 60 1510 Inlet Air Control Optional 12 60 127 Fluid Inlet 30 60 122 Plug 13 60 1119 CPR H2O CPR Gravity Gun Body 31 60 104 Air Inlet Fitting 14 98 0109 Allen Plug 51 401 Standard 700 mL Gravity Feed Cup Aluminum 15 See Air Cap Chart Fan Control Assembly 51 400 Optional 700 mL Gravity Feed Cup Plastic 16 See Air Cap Chart Fluid Needle 51 403 Option...

Page 4: ...01 11 CFM 23 1301 13 5 CFM 1 2 mm x 2101 or 1301 1 3 mm x 2101 or 1301 23 2101 13 23 1301 12 Revised 1 7 16 H2O CPR G PPS H2O CPR G EP H2O CPR G Includes 51 401 700 mL Aluminum Gravity Cup 98 0104 3 8 Socket 98 0112 Ratchet Wrench 60 8001 Gun Wrench 98 0113 Gun Cleaning Brush Air Caps and Needles Shown on Page 1 EP H2O CPR G PPS Includes 91 465 650 mL PPS Cup and Collar 91 466 Lids and Liners Avai...